Haier CWH18A Air Conditioner User Manual


 
6
To test your power supply cord:
1. Plug the power supply cord into a grounded 3 prong outlet.
2. Press RESET (on some devices, a green light will turn on).
3. Press TEST (listen for click; Reset button will trip, and on
some devices, a green light will turn off).
4. Press and release RESET (listen for click; Reset button will
latch, and on some devices, a green light will turn on). The
power supply cord is ready for operation.
NOTES:
The Reset button must be pushed in for proper operation.
The power supply cord must be replaced if it fails to trip when
the test button is pressed or fails to reset.
Do not use the power supply cord as an off/on switch. The
power supply cord is designed as a protective device.
A damaged power supply cord must be replaced with a new
power supply cord obtained from the product manufacturer
and must not be repaired.
The power supply cord contains no user serviceable parts.
Opening the tamper-resistant case voids all warranty and
performance claims.
INSTALLATION INSTRUCTIONS
Unpack the Air Conditioner
Remove packaging materials
Remove and dispose of/recycle packaging materials.
Remove tape and glue residue from surfaces before turning
on the air conditioner. Rub a small amount of liquid dish soap
over the adhesive with your fingers. Wipe with warm water
and dry.
Do not use sharp instruments, rubbing alcohol, flammable
fluids, or abrasive cleaners to remove tape or glue. These
products can damage the surface of your air conditioner.
Handle the air conditioner gently.
1. Remove the air conditioner from the carton and place it on
cardboard.
2. Remove the screws that attach the front panel to the air
conditioner cabinet on both sides of the air conditioner.
3.
Remove the screws that attach the air conditioner cabinet to
the base on both sides of the air conditioner.
4. Remove the front panel from the air conditioner .
6. Remove the ground screw and ground wire from the front of
the air conditioner. Save the ground screw.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
WARNING
Excessive Weight Hazard
Use two or more people to move and install
air conditioner.
Failure to do so can result in back or other injury.
A.Green ground wire
B.Ground screw
A
B
A
5. Disconnet conneting wire and set the front panel aside.
Connecting wire
WARNING
A.Screw locations
A.Screw locations
A
Remove the screws inside the front panel that attach
* CWH18A:
the cabinet to the base on both sides.
* CWH12A,CWH24A: