Haier AC522AFERA Air Conditioner User Manual


 
3
Safety Precautions
WARNING!
DANGER!
Do not attempt to install this air conditioner by yourself.
This unit contains no user-serviceable parts. Always consult authorized service personnel
for repairs.
When moving, consult authorized service personnel for disconnection and installation of
the unit.
Do not become excessively chilled by staying for lengthy periods in the direct cooling
airflow.
Do not insert fingers or objects into the outlet port or intake grills.
Do not start and stop air conditioner operation by connecting and disconnecting the
power supply cord and so on.
Take care not to damage the power supply cord. If the supply card is damaged, it must be
replaied by the manufacturer or authoried service agent in order to avoid a hazard.
In the event of a malfunction (burning smell, etc.), stop operation immediately, turn off
the circuit breaker, and consult authorized service personnel.
The breaker of the air conditioner should be all-pole switch; and the distance between its
two contacts should be no less 3 mm. Such means for disconnection must be
incorporation in the fixed wiring.
Use copper wire only. All the cables shall have got the European authentication certificate.
The power supply connects from the outdoor side. The connectingcable and the power cable
are self-provided.
The parameter of connecting cable: H05RN-F 4G 0.75mm
2
.
The paramter of Indoor and Outdoor unit:T3.15A/250VAC.If the fuse on PC board is
broken, please change with the type.