All electrical repairs must be carried out by
qualified electricians. Inadequate repairs may
result in a major source of danger for the user
of the air conditoiner.
Do not damage any parts of the air conditioner
that carry refrigerant by piercing or perforating
the air conditioner's tubes with sharp or pointed
items, crushing or twisting any tubes, or
scraping the coatings off the surfaces. If the
refrigerant spurts out and gets into eyes, it may
result in serious eye injuries.
Do not obstruct or cover the ventilation grille
of the air conditioner. Do not put fingers or any
other things into the inlet/outlet and swing
louver.
Do not allow children to play with the air
conditioner. In no case should children be
allowed to sit on the outdoor unit.
Specifications
The refrigerating circuit is leak-proof.
1. Applicable ambient temperature range:
The machine is adaptive in following
situation
Cautions
Cooling
Heating
Indoor
outdoor
Rated Maximum Minimum
27 32 18
19 23 14
35 43 10
24 26 6
20 27 15
14.5 -- --
7 24 -15
6 18 --
DB C
WB C
DB C
WB C
Indoor
outdoor
DB C
WB C
DB C
WB C
Model
AC142XCERA
Communication cable
(sheilded wire)
power cable
H05RN-F 3G (1-2.5)mm
2
H05RN-F 2X(0.75-1.5)mm
2
AC182XCERA
H05RN-F 3G (1-2.5)mm
2
H05RN-F 2X(0.75-1.5)mm
2
3. If the fuse on PC board is broken, please change
it with the type T 3.15A/250VAC.
The air breaker should be all-pole switch. and the
distance between it's two contacts should no less than
3mm.
2. If the supply cord is damaged, it must be replaced
by the service agent or a similar qualified person.
4. The wiring method should be in line with the local
standard.
6. The waste battery shall be disposed properly.
7. Do not use this unit for any other purposes
except for the Cooling and the Heating,
Dehumidifying, and air-circulation of rooms
should be in ordinary dwellings.
8. If the air conditioner is used under higher
temperature condition than those listed, the built-
in protection circuit may operate to prevent
internal circuit damage. Also, during Cooling
and Dry modes, if the unit is used under
conditions of lower temperature than those listed
above, the heat-exchanger may freeze, leading
to water leakage and other damage.
5. The power cable and connecting cable are
selfprovided.
The requirement of the communication cable: