23
Trouble Shooting
Note:
1. Please contact the installers or distributors when trouble happens to repair it.
2. Turn the power off and power on again, if the failure code recurs, please inform the franchiser.
3. Failrue codes maked with are resumable.
Abnormal communication
between wired controller and
indoor unit PCB
Drainage system abnormal
6 TIMES
Pump motor disconnected, or at wrong
position, or the float switch broken down
or the float switch disconnected,or at
wrong position
*
*
*
*
*
*
*
*
Abnormal communication
between chip TMP/807 and
chip TMP/846
14 TIMES Faulty indoor unit PCB
TROUBLE SHOOTING
FAILURE CODE
(TIMER LED OF INDOOR
RECEIVER BOARD FLASHES
TIMES)
POSSIBLE REASONS
Faulty temperature sensor Tai
ONCE
Sensor disconnected, or broken, or at wrong
position, or short circuit
Faulty temperature sensor Tc1
Sensor disconnected, or broken, or at wrong
position, or short circuit
Faulty temperature sensor Tc2
3 TIMES
Sensor disconnected, or broken, or at wrong
position, or short circuit
Faulty temperature sensor Tm 4 TIMES
Sensor disconnected, or broken, or at wrong
position, or short circuit
Faulty EEPROM on indoor
unit PCB
5 TIMES Faulty indoor unit PCB
Abnormal communication
between indoor and outdoor unit
Wrong connection, or the wires be disconnected,
or wrong address setting of indoor units, or faulty
power supply or faulty PCB
Indoor unit address repeated
9 TIMES
Wrong setting of indoor unit address
Malfunction on outdoor unit 20 TIMES Check the outdoor unit failure code
TWICE
7 TIMES
Wrong connection, or use the wired controllerbe
disconnected, faulty PCB
8 TIMES