Haier AC12CS1ERA Air Conditioner User Manual


 
(1) The power source capacity must be the sum of the room air conditioner current and the current of other electrical
appliances. When the current contracted capacity is insufficient, change the contracted capacity.
(2) When the voltage is too low and the air conditioner is difficult to start, contact the power company the voltage raised.
(1) Always use a special branch circuit and install a special receptacle to supply power to the room air conditioner.
(2) Use a circuit breaker and receptacle matched to the capacity of the room air conditioner.
(3) The circuit breaker is installed in the permanent wiring. Always use a circuit that can trip all the poles of the wiring and
has an isolation distance of at least 3mm between the contacts of each pole.
(4) Perform wiring work in accordance with standards so that the room air conditioner can be operated safely and positively.
(5) Install a leakage circuit breaker in accordance with the related laws and regulations and electric company standards.
Match the terminal block numbers and connection cord colors with those of the outdoor unit. Erroneous wiring may cause
burning of the electric parts.
Connect the connection cords firmly to the terminal block. Imperfect installation may cause a fire.
Always fasten the outside covering of the connection cord with the cord clamp.(If the insulator is chafed, electric leakage
may occur.)
Always connect the ground wire.
Installation Procedure
16
Wiring of indoor unit
(2) Pull out the electrical component box.
(4) Wiring
1.Remove the cord clamp.
2.Process the end of the connection cords to the
dimensions shown in the right figure.
3.Connect the end of the connection cord fully into the
terminal block.
4.Fasten the connection cord with a cord clamp.
5.Fasten the end of the connection cord with the screw.
(3) Remove the electrical component box cover.
Base
Electrical component box cover
Remove the three tapping screws.
Electrical component box
Be careful not to pinch the lead wires
between the electrical component box
and base.
(1) Remove the electrical component box.
Electrical component box
Do not remove the screws. If the
screws are removed, the electrical
component box will fall.
Electrical component box
Remove the four tapping screws.
1(N) 2(L) 3(C)
Y/G
Y/G
Outdoor unit
terminal block
Indoor unit
terminal block
12 3
CAUTION:
CAUTION:
CAUTION:
WARNING:
CAUTION: