Haier AC12CS1ERA Air Conditioner User Manual


 
Select whether the drain hose will be
connected to the left or right side (Fig.2). Insert
the drain hose into the drain pan, then secure
the drain hose with a nylon fastener (Fig.5).
2. Installing drain hose
Wrap the insulation (drain hose) around the drain
hose connection. (Fig.6)
Drain pan
Drain hose
Nylon fastener
Drain pan
Drain hose
Insulation
(Drain hose)
Installation Procedure
12
Open the intake grill and remove the three or four or six screws.
Note:
The main unit can be wired before the indoor unit is installed.
Select the most appropriate installation order.
A.FLOOR CONSOLE TYPE
1.Drilling for piping
Select piping and drain directions. The piping and drain can be made
in three directions as shown in the Fig.1.
rear
right
down
Remove the intake grill
PREPARING INDOOR UNIT INSTALLATION
When installing set to wall, install the accessory wall
bracket at the position shown in Fig. 4, and mount the
set to it.
Wall bracket
Side of set
65.5cm
99cm
50cm
24.5cm
6.5cm
12.5cm 10cm
6.5cm
53cm
4.5cm
7cm hole
3.5cm hole
The drain hose can be connected to either the left or right side. (Fig.2)
Wall
7cm
6mm
Indoor unit outdoor unit
When the directions are selected, drill a 7 cm dia. hole on the wall so
that the hole is tilted downward toward the outdoor for smooth water
flow. When the pipe is led out from the rear, make a hole at the position
shown in Fig.3.
Drain hose (Left side) Drain hose (Right side)
Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Intake grill