Haier AB242XCAAA Air Conditioner User Manual


 
Operation
13
Power Failure Compensation (to be applied for a necessary situation)
After the power failure compensation is set, if power failure suddenly occurs while the air conditioner
is working, it will resume the previous working state when the power is supplied again.
Setting Method: When the wire controller is on (excluding timer mode and fan mode), press
the "Sleeping" button on the remote controller 10 times within 5 seconds, and
after the buzzer rings 4 times, the air conditioner will enter the state of power
failure compensation.
Cancel Method: Press the "Sleeping" button on the wire controller 10 times within 5 seconds,
and after the buzzer rings 2 timer, the power failure compensation mode will be
cancelled.
Notes: When a power failure suddenly occurs during the air conditioner is working after the power
failure compensation is set, if the air conditioner will not be used for a long time, please cut off the
power supply to prevent its operation from being resumed after the power is supplied again, or press
the "Switch On/Off" button after the power comes again.
In this series changeover switch is set:
1. OFF 2.OFF 3.ON 4.OFF
Change-over switch
Mark
1
2
3
ON
Inverter
Have rise and drop
Swing
OFF
Fixed Frequency
No rise and drop
Not Swing
4
The collection
temperature of
indoor unit
The collection
temperature of wire
controller.