Haier AB182XCERA Air Conditioner User Manual


 
8.Electrical Wiring
Wiring methods:
1 Wiring method of ring terminal
For connecting line which end is a ring,its wiring method
as shown in the right figure: remove wiring screw and pass
it through the end ring of connecting line,then connect it to
the terminal block and tighten screw.
Wiring method of ring terminal
17
2 Wiring of indoor unit
The distance between the signal wires and the power cabes should be at least 50mm.
C
BA
Q
P
1(L) 2(N) 2(N)1(L)
P
Q
A B
C
L N
C1 C2
(In case of using wired
controller)
To other
indoor unit
To wired controller
To outdoor unit
L N
Ring Terminal
Installation Procedures
1.Incorrect address setting will cause abnormal to the system.
2.Communication cable must be use sheilded type.
3.Communication cable and power cable must be use ring terminal type.
Communication cable (Shield wire):
H05RN-F 2X (0.75-1.5)mm
2
Power cable : H05RN-F 3G (1-2.5)mm
2
WARNING
T
B
Brazed seam
B=8.0-9.0(mm)
d=4.3-5.3(mm)
T=1.0-2.0(mm)
(For your referrence)
d