Check Valve Repair
Disassembly
1. Relieve the pressure. Disconnect all hoses.
2. Remove the pump from its mounting. Drain.
3. From the outlet manifold, remove both upper clamps
(132a).
4. Remove outlet manifold leaving elbows (128), gas-
kets (129), clamps (130), and tee (339) assembled.
5. For 3A Ball Check pumps: remove ball gasket (240).
Remove middle clamp (132c) and ball stop housing
(2XA). Remove middle gasket (240) and ball (541).
Remove lower clamp (132b), seat (2XB), and gasket
(240). Clean all parts and inspect for wear or dam-
age. Replace parts as needed.