Haier 0010571564 Air Conditioner User Manual


 
The Creepage breaker must be installed.
If not installing Creepage breaker may easily cause electric shock.
After wiring, please power on the unit to detect electricity leakage.
If the power cable is damaged, in order to avoid danger, it must be changed by
the manufacturer or its repair center or the similar professional personnel. For
the power cable of indoor unit, please mate it according to the manual of indoor
unit.
Avoid the electric wire touching the high temperature part of the connection
pipe, in order not to the insulation part of the cable be melted causing accidents.
After connecting to the terminal block, the connection wire should be bent to
a U-shaped bend and use wire presser to fix.
Before performing vacuumizing the refrigerant pipe system, do not power on
the outdoor unit,
The power cable of indoor unit and the connection wire of indoor and outdoor
unit should be complied with what the operation manual of indoor unit specified.
The connection of power cable should be complied with the local wiring
regulations.
When wiring on site, choose the specification of wire and creepage breaker as
follows:
Notice
Electric wiring
Warning
Power supply
10
1PH, 220V, 50Hz
16
Below 50m
Below 20m
The minimum section area of wire
(mm
2
) (the connection wire of metal
pipe and synthetic resin pipe )
Capacity
Fuse
Knife switch
(A)
Creepage breaker
40A, 100mA, below 0.1s
40
The wiring work should commissioned to a qualified worker according to the
installation manual to perform. The air conditioner must use special power circuit.
Insufficient power capacity or improper work may cause electric shock and fire.
When wiring, the power cable must use the specified cable to firmly connect
and fix. Do not let the external force of the cable transfer to the terminal block.
Improper connection or fixation may cause heat and fire, etc. accident.
Must connect with grounding wire.
Connect with grounding wire as specified. Unreliable grounding may lead to
electric shock. Do not connect the grounding wire on the gas pipe, city water
pipe, lightning rod or telephone line.
Use the fuse with proper specification. Do not use wire or any other material to
replace fuse, otherwise it may cause damage of unit or fire.
40
7