Graco Inc. 260102 Septic System User Manual


 
Operation
311305E 5
Electrical Installation
115 VAC and 230 VAC
The 115 VAC models (260101 and 260102)
come wired with a short power cord and a
grounded electrical plug. Power to the unit
must be 115 VAC single phase. If an extension
cord is required, it should be a 3-wire cord with
a ground. Use a 20 amp circuit to supply power
to the pump.
The 230 VAC model (260104) is not shipped
with a power cord and plug. You must pur-
chase and install an appropriate power cord
and plug that meets your local electrical codes.
Electrical Installation
12 VDC
The 12 VDC model (260100) is not shipped
with a power cord since the installation will
determine the length of the power cord.
1. Verify the on/off switch is in the off position.
2. Remove the wiring junction box cover by
removing the four screws.
3. Use 10 AWG wire to connect the red (+)
and black (-) wires to the 12 VDC supply.
4. Reattach the wiring junction box cover with
the four screws.
Operation
1. On/Off switch is located on the motor (9).
Move switch to ON position.
2. Insert nozzle into container or fill tube and
open nozzle to dispense fluid.
3. Close nozzle to stop flow. The pump has an
internal bypass valve that will bypass the
fluid internally with nozzle closed.
4. Immediately after dispensing, turn switch to
OFF position.
Pressure Relief Procedure
1. Verify pump switch is OFF.
2. Open nozzle to relieve any residual pres-
sure.
3. To prevent damage to the pump, use inlet
suction screen (260306) when pumping
used oils.
CAUTION
Do not operate pump dry. Do not run pump for
more than 5 minutes with nozzle closed.
See Parts, page 8 for items referenced in
parentheses, i.e., (17).