Graco 3A1334F Water Pump User Manual


 
Operation
3A1334F 13
5. Examine follow plate to make sure rubber grommet
(c) is in place in center of the plate (F
IG. 7).
6. Set follow plate on top of fresh grease (F
IG. 8).
Remove air by pushing on the follow plate until the
grease level is flush with the opening in the middle
of the follow plate (d).
7. Insert pump drop tube through center of rubber
grommet in follow plate (F
IG. 9).
Se
8. Tighten thumb screws (a) to secure cover to drum.
9. For the pump that is connected, trigger the dispens-
ing valve into a grounded metal waste container
making firm, metal-to-metal contact between the
container and the valve.
10. Slowly open the bleed-type master air valve and
open the pump air regulator just until the pump is
running. When the pump is primed and all air has
been pushed out of the lines, release the trigger.