Power Module
3A0246C 7
Power Module
Removal
1. Perform Pressure Relief Procedure, see page 4.
Unplug power cord.
2. Release hopper adapter clamp (158).
3. Loosen rod clamp knob (112) on front of pump mod-
ule and push rod down.
4. Lift and pull power module (153) off of unit.
NOTE: Power module weighs approximately 85 lb.
5. Install hopper plug (117) if needed.
Installation
1. Remove hopper plug (117) if installed.
2. Replace power (153) module and insert pump outlet
into hopper inlet.
3. Pull rod clamp up and tighten knob (112) on front of
pump module.
4. Fasten hopper adapter clamp (158).
ti15684a
158
ti11675a
112
ti15623a
153
ti15623a
117
ti15625a
153
ti11678a
112
ti15683a
158