Graco 224348 Heat Pump User Manual


 
25308118
Technical Data (5:1 Monark)
Fluid Outlet Pressure Chart
0
200
400
600
800
012345
PUMP DELIVERY (Test Fluid: No. 10 Motor Oil)
PUMP OUTLET PRESSURE
12024 48 72
CPM
96
3.8 7.6 11.4 15.2 19.0
GPM
l/min
A
B
C
4.2, 42
PSI
5.6, 56
2.8, 28
MPa, BAR
To find Outlet Pressure (MPa/bar/psi) at a specific
delivery (liter/min or gpm) and operating air pressure
(MPa/bar/psi):
1. Locate desired delivery along bottom of chart.
2. Read vertical line up to intersection with
selected fluid outlet pressure curve.
Curve slopes from left to right.
Follow left to scale and read outlet pressure.
A 1.25 MPa, 12.5 bar (180 psi) air pressure
B 0.7 MPa, 7 bar (100 psi) air pressure
C 0.49 MPa, 4.9 bar (70 psi) air pressure
D 0.28 MPa, 2.8 bar (40 psi) air pressure
1.4, 14
D
Air Consumption Chart
0
8
16
24
32
40
012345
PUMP DELIVERY (Test Fluid: No. 10 Motor Oil)
AIR CONSUMPTION
24 48 72 96
CPM
120
3.8 7.6 11.4 15.2 19.0
GPM
l/min
1.120
CFMm
3
/min
0.224
0.448
0.672
A
B
C
To find Pump Air Consumption (m
3
/min or
CFM/min) at a specific delivery (liter/min or gpm)
and operating air pressure (MPa/bar/psi):
1. Locate desired delivery along bottom of chart.
2. Read vertical line up to intersection with
selected air consumption curve.
Curve slopes from right to left. Follow left to
scale and read air consumption.
A 1.25 MPa, 12.5 bar (180 psi) air pressure
B 0.7 MPa, 7 bar (100 psi) air pressure
C 0.49 MPa, 4.9 bar (70 psi) air pressure
D 0.28 MPa, 2.8 bar (40 psi) air pressure
D
0.896