307674 17
Technical Data
Category Data
Ratio 3:1
Maximum fluid working pressure 360 psi (2.5 MPa, 25 bar)
Maximum air input pressure 120 psi (0.8 MPa, 8.3 bar)
Pump cycles per 1 gallon (3.8 liters) 6
Fluid flow at 60 cycles per minute 10 gpm (38 liters/min)
Fluid inlet size 1–1/2 npt(f)
Fluid outlet size 1 in. npt(f)
Air inlet size 3/8 npsm(f)
Weight 47 lb (21.32 kg)
Maximum pump operating temperature 180_F (82_C)
* Sound level at 100 psi, 60 cycles per minute 94 dBa
* Sound power level at 100 psi, 60 cycles per minute 109 dBa
Wetted parts Supply and Return Tubes: Stainless steel
Air Motor Base: Aluminum
Displacement Pump: Refer to manual 307652
* Tested in accordance with ISO 3744.
0
50
100
150
200
250
300
350
400
0.0 2.5 5.0 7.5 10.0
0
5
10
15
20
25
30
35
40
0.0 2.5 5.0 7.5 10.0
cycles per min
15 30 45 60
9.5 19 29 38liters/min
gpm
FLUID FLOW (TEST FLUID: NO 10 MOTOR OIL)
m#/min
scfm
0.560
0.420
0.140
0.280
0.700
0.840
0.980
1.120
AIR CONSUMPTION
cycles per min
15 30 45 60
bar
psi
9.5 19 29 38liters/min
gpm
FLUID FLOW (TEST FLUID: NO 10 MOTOR OIL)
To find Fluid Outlet Pressure (bar/psi) at a specific fluid flow (lpm/
gpm) and operating air pressure (bar/psi):
1. Locate desired flow along bottom of chart.
2. Follow vertical line up to intersection with selected fluid outlet
pressure curve. Follow left to scale and read fluid outlet pressure.
To find Pump Air Consumption (m#/min or scfm) at a specific fluid
flow (lpm/gpm) and operating air pressure (bar/psi):
1. Locate desired flow along bottom of chart.
2. Follow vertical line up to intersection with selected air consump-
tion curve. Follow left to scale and read air consumption.
3.5
7
17.5
21
24.5
28
A 100 psi (7 bar) air pressure
B 70 psi (4.9 bar) air pressure
C 40 psi (2.8 bar) air pressure
A
A
B
B
C
C
14
10.5
FLUID OUTLET PRESSURE
Fluid Outlet Pressure Chart Air Consumption Chart
Performance Charts