Goodman Mfg SSZ 14 SEER Heat Pump User Manual


 
22
EXPANDED PERFORMANCE DATA
MODEL: SSZ140361A* / CA*F4860C6A*+TXV / MBR1600**-1 HEATING OPERATION
Outdoor Ambient Temperature
65 60 55 50 47 45 40 35 30 25 20 17 15 10 5 0 -5 -10
MBh 43.5 41.2 38.8 36.2
34.6
33.5 31.1 28.7 28.8 26.6 24.5 23.1 22.3 20.0 17.7 15.5 13.2 10.8
Delta T 38.4 36.3 34.2 31.9 30.5 29.6 27.5 25.3 25.4 23.5 21.6 20.4 19.6 17.6 15.6 13.6 11.6 9.5
KW 3.05 2.99 2.94 2.88
2.84
2.82 2.76 2.71 2.78 2.72 2.66 2.62 2.60 2.53 2.47 2.41 2.35 2.29
AMPS 13.8 12.8 12.0 11.3 10.9 10.7 10.1 9.6 9.2 8.9 8.4 8.3 8.2 7.8 7.3 6.9 6.4 5.8
COP 4.17 4.02 3.86 3.68 3.56 3.48 3.30 3.11 3.03 2.86 2.70 2.58 2.51 2.31 2.10 1.87 1.64 1.38
EER 14.3 13.8 13.2 12.6 12.2 11.9 11.3 10.6 10.4 9.8 9.2 8.8 8.6 7.9 7.2 6.4 5.6 4.7
HI PR 384 368 353 338 330 324 311 299 286 273 262 256 251 242 233 223 215 208
LO PR144134125115109105968677696156544640332923
EXPANDED PERFORMANCE DATA
MODEL: SSZ140301A* / CA*F3642*6A*+TXV / MBR1600**-1 HEATING OPERATION
Outdoor Ambient Temperature
65 60 55 50 47 45 40 35 30 25 20 17 15 10 5 0 -5 -10
MBh 36.5 34.5 32.5 30.4
29.0
28.1 26.1 24.1 22.6 20.9 19.2 18.2 17.5 15.7 13.9 12.1 10.3 8.5
Delta T32.130.428.626.8 25.6 24.823.021.219.918.417.016.015.413.812.310.7 9.1 7.5
KW 2.40 2.36 2.32 2.27
2.25
2.23 2.19 2.14 2.20 2.15 2.11 2.08 2.06 2.01 1.97 1.92 1.87 1.83
AMPS 11.8 10.6 9.6 8.7 8.2 8.0 7.2 6.6 6.1 5.6 5.1 4.9 4.8 4.3 3.6 3.1 2.5 1.8
COP 4.444.284.103.91 3.78 3.693.503.293.012.842.672.552.482.282.071.851.621.36
EER 15.2 14.6 14.0 13.4 12.9 12.6 11.9 11.2 10.3 9.7 9.1 8.7 8.5 7.8 7.1 6.3 5.5 4.6
HI PR 360 346 332 318 310 304 292 281 269 257 247 241 236 227 219 210 202 195
LO PR 137 127 119 110 104 100 92 82 74 66 58 54 52 44 38 32 28 22
EXPANDED PERFORMANCE DATA
MODEL: SSZ140241A* / CA*F3636*6A*+TXV / MBR800**-1 HEATING OPERATION
Outdoor Ambient Temperature
65 60 55 50 47 45 40 35 30 25 20 17 15 10 5 0 -5 -10
MBh 30.2 28.6 26.9 25.1
24.0
23.3 21.6 19.9 17.9 16.6 15.2 14.4 13.9 12.4 11.0 9.6 8.2 6.7
Delta T32.931.129.327.4 26.1 25.323.521.719.518.016.615.715.113.512.010.5 8.9 7.3
KW 2.08 2.04 2.00 1.96
1.94
1.92 1.89 1.85 1.87 1.82 1.78 1.76 1.74 1.70 1.66 1.62 1.58 1.54
AMPS 8.1 7.9 7.7 7.5 7.4 7.3 7.2 7.1 7.0 6.9 6.8 6.7 6.7 6.6 6.5 6.3 6.2 6.1
COP 4.24 4.09 3.93 3.74 3.62 3.54 3.35 3.16 2.81 2.65 2.50 2.39 2.33 2.14 1.94 1.73 1.52 1.28
EER 14.5 14.0 13.4 12.8 12.4 12.1 11.4 10.8 9.6 9.1 8.5 8.2 7.9 7.3 6.6 5.9 5.2 4.4
HI PR 373 358 344 329 321 315 303 290 278 266 255 249 245 235 226 217 209 202
LO PR 143 133 124 114 108 104 95 85 77 68 60 56 54 46 39 33 29 23
EXPANDED PERFORMANCE DATA
MODEL: SSZ140181A* / CA*F3131*6A* +TXV / MBR800**-1 HEATING OPERATION
Outdoor Ambient Temperature
65 60 55 50 47 45 40 35 30 25 20 17 15 10 5 0 -5 -10
MBh 22.6 21.4 20.2 18.8
18.0
17.4 16.2 14.9 12.8 11.8 10.9 10.3 9.9 8.9 7.9 6.9 5.9 4.8
Delta T34.933.131.129.1 27.8 26.925.023.119.718.216.815.815.313.712.110.6 9.0 7.4
KW 1.56 1.53 1.50 1.47
1.45
1.44 1.41 1.38 1.39 1.36 1.32 1.31 1.29 1.26 1.23 1.20 1.17 1.14
AMPS 7.0 6.5 6.1 5.7 5.5 5.4 5.1 4.9 4.7 4.5 4.2 4.1 4.1 3.9 3.6 3.4 3.2 2.9
COP 4.23 4.09 3.93 3.75 3.62 3.54 3.36 3.16 2.70 2.55 2.40 2.30 2.24 2.06 1.87 1.67 1.47 1.23
EER 14.5 14.0 13.4 12.8 12.4 12.1 11.5 10.8 9.2 8.7 8.2 7.9 7.6 7.0 6.4 5.7 5.0 4.2
HI PR 385 369 355 339 331 325 312 300 287 274 263 257 252 243 234 224 216 208
LO PR 149 138 129 118 112 108 99 88 80 71 62 58 56 47 41 34 30 24
SPLIT SYSTEM HEATING PERFORMANCE
High pressure is measured at the suction service valve ( the larger valve). AMPS = Outdoor unit amps (comp.+fan)
Low pressure is measured at the gauge port connection. KW = Total system power
Calculations are based on nominal CFM and 70 °F indoor dry bulb.
*Note: Shaded area is ARI Rating Conditions at 47° outdoor ambient temberature