Goodman Mfg SS-GSH10C Heat Pump User Manual


 
pRoduCt SpECifiCationS
pRoduCt SpECifiCationS
10 www.goodmanmfg.com SS-GSH10C
ExpandEd HEatinG data


                 
MBh 103.1 97.6 91.8 85.9 82.0 79.5 73.8 68.1 66.0 61.0 56.1 53.0 51.0 45.8 40.6 35.4 30.2 24.8
∆T 33.1 31.4 29.5 27.6 26.4 25.5 23.7 21.9 21.2 19.6 18.0 17.0 16.4 14.7 13.1 11.4 9.7 8.0
kW 8.04 7.89 7.74 7.59 7.50 7.44 7.29 7.14 7.48 7.32 7.16 7.06 7.00 6.83 6.67 6.51 6.34 6.18
Amps 24.4 22.6 21.1 19.8 19.1 18.7 17.6 16.7 16.0 15.3 14.5 14.2 14.0 13.3 12.4 11.6 10.7 9.6
COP 3.75 3.62 3.47 3.31 3.20 3.13 2.96 2.79 2.58 2.44 2.30 2.20 2.14 1.96 1.78 1.59 1.39 1.17
EER 12.8 12.4 11.9 11.3 10.9 10.7 10.1 9.5 8.8 8.3 7.8 7.5 7.3 6.7 6.1 5.4 4.8 4.0
Hi PR 244 234 225 215 210 206 198 190 182 174 167 163 160 154 148 142 137 132
Lo PR 72 66 62 57 54 52 48 43 38 34 30 28 27 23 20 17 15 11


                 
MBh 105.8 100.1 94.2 88.1 84.1 81.5 75.7 69.8 64.1 59.1 54.5 51.4 49.5 44.4 39.4 34.3 29.3 24.0
∆T 32.1 30.4 28.6 26.7 25.5 24.8 23.0 21.2 19.5 18.0 16.5 15.6 15.0 13.5 12.0 10.4 8.9 7.3
kW 8.03 7.88 7.73 7.58 7.49 7.42 7.28 7.12 7.95 7.77 7.59 7.49 7.42 7.24 7.06 6.88 6.70 6.52
Amps 30.2 28.1 26.4 24.9 24.1 23.7 22.4 21.4 20.5 19.7 18.8 18.4 18.2 17.4 16.3 15.5 14.4 13.2
COP 3.85 3.72 3.57 3.40 3.29 3.21 3.05 2.87 2.36 2.23 2.10 2.01 1.95 1.80 1.63 1.46 1.28 1.08
EER 13.2 12.7 12.2 11.6 11.2 11.0 10.4 9.8 8.1 7.6 7.2 6.9 6.7 6.1 5.6 5.0 4.4 3.7
Hi PR 268 257 247 236 230 226 217 209 200 191 183 179 176 169 162 156 150 145
Lo PR 72 67 63 57 54 52 48 43 39 34 30 28 27 23 20 17 15 11


                 
MBh 132.6 125.5 118.2 110.5 105.5 102.2 95.0 87.6 85.4 78.8 72.5 68.5 66.0 59.2 52.5 45.8 39.0 32.0
∆T 30.7 29.1 27.4 25.6 24.4 23.7 22.0 20.3 19.8 18.2 16.8 15.9 15.3 13.7 12.1 10.6
9.0 7.4
kW 10.41 10.21 10.01 9.81 9.70 9.62 9.43 9.23 9.69 9.47 9.26 9.13 9.05 8.83 8.62 8.41 8.19 7.98
Amps 28.3 26.2 24.5 23.0 22.1 21.7 20.4 19.3 18.4 17.6 16.7 16.3 16.1 15.2 14.1 13.3 12.2 10.9
COP 3.73 3.60 3.45 3.29 3.18 3.11 2.95 2.78 2.58 2.44 2.29 2.20 2.13 1.96 1.78 1.59 1.40 1.17
EER 12.7 12.3 11.8 11.3 10.9 10.6 10.1 9.5 8.8 8.3 7.8 7.5 7.3 6.7 6.1 5.4 4.8 4.0
Hi PR 221 212 203 195 190 186 179 172 165 157 151 147 145 139 134 128 124 120
Lo PR 66 62 58 53 50 48 44 39 36 32 28 26 25 21 18 15 13 11
High pressure is measured at the sucon service valve ( the larger valve). Amps = Outdoor unit amps (comp.+fan)
Low pressure is measured at the gauge port connecon. kW = Total system power
Calculaons are based on nominal CFM and 70 °F indoor dry bulb.