pRodUCt SpECifiCationS
pRodUCt SpECifiCationS
12 www.goodmanmfg.com SS-GPH13MC
SS-GPH13MC www.goodmanmfg.com 13
aiRflow data
  

0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
GPH13
36M43*
Low 230
CFM 1122 1078 1032 972 915 804 687 558
Was 338 330 321 310 300 283 264 250
Med 230
CFM 1387 1331 1264 1209 1119 1041 935 748
Was 456 440 428 412 399 382 363 330
High 230
CFM 1521 1454 1388 1311 1230 1144 1055 939
Was 534 521 510 490 477 461 442 420
GPH13
48M43*
T1 (G) 230
CFM 1,440 1,395 1,360 1,310 1,265 1,235 1,190 1,130
Was 275 285 295 315 325 335 345 355
T2 / T3
(W2)
230
CFM 1,795 1,765 1,715 1,695 1,650 1,600 1,500 1,375
Was 475 490 505 520 530 535 510 475
T4 / T5 (Y) 230
CFM 1,860 1,820 1,785 1,745 1,700 1,625 1,515 1,395
Was 515 530 545 565 570 550 535 485
GPH13
60M43*
T1 (G) 230
CFM 1,755 1,720 1,685 1,645 1,615 1,570 1,530 1,465
Was 420 435 455 460 475 490 500 500
T2 / T3
(W2)
230
CFM 1,850 1,820 1,775 1,735 1,705 1,675 1,610 1,495
Was 480 500 515 525 535 555 545 520
T4 / T5 (Y) 230
CFM 2,180 2,125 2,050 1,975 1,875 1,800 1,655 1,530
Was 770 755 725 700 675 640 575 540

Data shown is dry coil. Wet coil pressure drop is approximately 0.1" H₂O, for two-row indoor coil; 0.2” H₂O, for three-row indoor coil; and 0.3” H₂O, for four-
row indoor coil.
Data shown does not include lter pressure drop, approx. 0.08” H2O.
ALL MODELS SHOULD RUN NO LESS THAN 350 CFM/TON. USE HIGHER SPEED TAP OR NEXT SIZE LARGER BLOWER ASM. See Repair Parts list.
Reduce airow by 2% for 208-volt operaon.