Goodman Mfg SS-GME8 Furnace User Manual


 
ProDuct sPeciFications
ProDuct sPeciFications
SS-GME8 www.goodmanmfg.com 5
airFlow Data







0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
CFM  CFM  CFM  CFM  CFM  CFM CFM CFM
GME8
0703BXC*
T1 875 59 793 65 736 70 674 77 592 88 556 509 460
T2 2 1,032 50 965 54 914 57 861 60 810 64 756 712 659
T3 1,217 43 1,153 45 1,098 47 1,051 49 1,009 51 964 918 877
T4 3 1,365 38 1,313 39 1,268 41 1,221 42 1,172 44 1,129 1,086 1,054
T5 1,549 33 1,505 34 1,460 36 1,420 37 1,378 38 1,350 1,305 1,268
GME8
0905CXC*
T1 1,268 53 1,198 56 1,151 58 1,092 61 1,041 64 988 932 883
T2 3 1,362 49 1,305 51 1,261 53 1,212 55 1,170 57 1,121 1,074 1,021
T3 1,576 42 1,519 44 1,473 45 1,426 47 1,398 48 1,341 1,290 1,252
T4 4 1,755 38 1,711 39 1,657 40 1,627 41 1,579 42 1,548 1,502 1,463
T5 5 2,183 31 2,128 31 2,094 32 2,060 32 2,014 33 1,992 1,944 1,847
GME8
1155CXC*
T1 3 1,466 58 1,415 60 1,357 63 1,306 65 1,248 68 1,202 1,144 1,088
T2 1,642 52 1,596 53 1,552 55 1,499 57 1,449 59 1,388 1,352 1,306
T3 4 1,750 49 1,750 49 1,707 50 1,667 51 1,610 53 1,574 1,531 1,486
T4 4 1,870 46 1,805 47 1,782 48 1,737 49 1,701 50 1,656 1,606 1,571
T5 5 2,297 37 2,297 37 2,224 38 2,106 40 2,014 42 1,896 1,813 1,669
¹ @ 0.5” ESP

CFM in chart is without lter(s). Filters do not ship with this furnace, but must be provided by the installer. If the furnace requires two return lters,
this chart assumes both lters are installed.
All furnaces ship as high-speed cooling and medium-speed heang. Installer must adjust blower cooling and heang speed as needed.
For most jobs, about 375 - 400 CFM per ton when cooling is desirable.
INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE.
This chart is for informaon only. For sasfactory operaon, external stac pressure should not exceed value shown on the rang plate.
The above chart is for U.S. furnaces installed at 0-2000 feet. At higher altudes, a properly derated unit will have approximately the same
temperature rise at a parcular CFM, while ESP at the CFM will be lower.
Factory Motor Speed Seng: T1 = 1st Stage Ht, T2 = 2nd Stage Ht, T5 = Cooling
Tempertaure rise data is based on 2nd-stage heat. First-stage heat is 75% of rise indicated above.