Goodman Mfg RT6213004 Heat Pump User Manual


 
18
COOLING PERFORMANCE DATA GSH140601A*
EXPANDED PERFORMANCE DATA
COOLING OPERATION
MODEL: GSH140601A* / CA*F4860D6A* +TXV / MBR2000**-1 Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions
Outdoor Ambient Temperature
65 75 85 95 105 115
Entering Indoor Wet Bulb Temperature
IDB*Airflow 596367715963 67 7159636771596367715963677159636771
MBh 54.4 56.4 61.8 - 53.1 55.1 60.3 - 51.9 53.7 58.9 - 50.6 52.4 57.5 - 48.1 49.8 54.6 - 44.5 46.1 50.6 -
S/T 0.76 0.64 0.44 - 0.79 0.66 0.46 - 0.81 0.68 0.47 - 0.84 0.70 0.48 - 0.87 0.73 0.50 - 0.88 0.73 0.51 -
Delta T 18 16 12 - 19 16 12 - 19 16 12 - 19 16 12 - 18 16 12 - 17 15 11 -
1744 KW 3.32 3.39 3.49 - 3.57 3.65 3.77 - 3.80 3.88 4.01 - 4.00 4.09 4.22 - 4.17 4.26 4.40 - 4.31 4.41 4.56 -
AMPS 12.1 12.4 12.8 - 13.1 13.4 13.9 - 14.2 14.6 15.1 - 15.2 15.6 16.1 - 16.2 16.6 17.2 - 17.2 17.6 18.2 -
HI PR 132 142 150 - 148 160 169 - 169 182 192 - 192 207 218 - 216 233 246 - 239 257 271 -
LO PR 59 63 69 - 63 67 73 - 65 69 76 - 69 73 80 - 72 76 83 - 74 79 86 -
MBh 52.8 54.7 60.0 - 51.6 53.5 58.6 - 50.3 52.2 57.2 - 49.1 50.9 55.8 - 46.7 48.4 53.0 - 43.2 44.8 49.1 -
S/T 0.73 0.61 0.42 - 0.75 0.63 0.44 - 0.77 0.65 0.45 - 0.80 0.67 0.46 - 0.83 0.69 0.48 - 0.84 0.70 0.48 -
Delta T 19 17 13 - 19 17 13 - 19 17 13 - 19 17 13 - 19 17 13 - 18 16 12 -
70 1550 KW 3.29 3.36 3.47 - 3.54 3.62 3.74 - 3.77 3.85 3.98 - 3.97 4.05 4.19 - 4.13 4.23 4.37 - 4.28 4.37 4.52 -
AMPS 12.0 12.3 12.7 - 13.0 13.3 13.7 - 14.1 14.5 14.9 - 15.1 15.5 16.0 - 16.1 16.5 17.0 - 17.1 17.5 18.1 -
HI PR 131 141 149 - 147 158 167 - 167 180 190 - 190 205 216 - 214 230 243 - 236 254 269 -
LO PR 59 63 68 - 62 66 72 - 65 69 75 - 68 72 79 - 71 76 83 - 74 78 85 -
MBh 48.7 50.5 55.3 - 47.6 49.3 54.1 - 46.5 48.2 52.8 - 45.3 47.0 51.5 - 43.1 44.6 48.9 - 39.9 41.4 45.3 -
S/T 0.70 0.59 0.41 - 0.73 0.61 0.42 - 0.75 0.62 0.43 - 0.77 0.64 0.45 - 0.80 0.67 0.46 - 0.81 0.67 0.47 -
Delta T 19 17 13 - 20 17 13 - 20 17 13 - 20 17 13 - 20 17 13 - 18 16 12 -
1356 KW 3.21 3.28 3.38 - 3.46 3.53 3.65 - 3.68 3.76 3.88 - 3.87 3.95 4.08 - 4.03 4.12 4.25 - 4.17 4.26 4.40 -
AMPS 11.7 11.9 12.3 - 12.6 12.9 13.3 - 13.7 14.1 14.5 - 14.7 15.0 15.5 - 15.6 16.0 16.6 - 16.6 17.0 17.6 -
HI PR 127 137 144 - 142 153 162 - 162 174 184 - 185 199 210 - 208 223 236 - 229 247 261 -
LO PR 57 61 66 - 60 64 70 - 63 67 73 - 66 70 76 - 69 73 80 - 71 76 83 -
MBh 55.3 56.9 61.6 66.2 54.0 55.6 60.2 64.6 52.7 54.3 58.8 63.1 51.4 53.0 57.3 61.5 48.9 50.3 54.5 58.5 45.3 46.6 50.5 54.2
S/T 0.87 0.78 0.59 0.38 0.90 0.80 0.61 0.39 0.92 0.82 0.62 0.40 0.95 0.85 0.64 0.41 0.99 0.88 0.67 0.43 1.00 0.89 0.67 0.43
Delta T212016112120 16 11212016112220 16 11 21 20 16 11 20 18 15 10
1744 KW 3.34 3.42 3.52 3.64 3.60 3.68 3.80 3.92 3.83 3.91 4.04 4.18 4.03 4.12 4.26 4.40 4.20 4.30 4.44 4.59 4.35 4.45 4.60 4.75
AMPS 12.2 12.5 12.9 13.4 13.2 13.5 14.0 14.5 14.4 14.7 15.2 15.8 15.4
15.8
16.3 16.9 16.4 16.8 17.4 18.0 17.4 17.8 18.4 19.1
HI PR 134 144 152 158 150 161 170 178 170 183 194 202 194 209 221 230 218 235 248 259 241 260 274 286
LO PR 60 64 70 74 63 67 74 78 66 70 77 82 69 74 80 86 73 77 84 90 75 80 87 93
MBh 53.7 55.3 59.8 64.2 52.4 54.0 58.4 62.7 51.2 52.7 57.1 61.2 50.0 51.4 55.7 59.7 47.5 48.9 52.9 56.8 44.0 45.3 49.0 52.6
S/T 0.83 0.74 0.56 0.36 0.86 0.77 0.58 0.37 0.88 0.79 0.59 0.38 0.91 0.81 0.61 0.40 0.94 0.84 0.64 0.41 0.95 0.85 0.64 0.41
Delta T222017112221 17 12222117122321 17 12 22 20 17 12 21 19 16 11
75 1550 KW 3.32 3.39 3.50 3.61 3.57 3.65 3.77 3.89 3.80 3.88 4.01 4.14 4.00
4.09
4.22 4.36 4.17 4.26 4.40 4.55 4.31 4.41 4.56 4.71
AMPS 12.1 12.4 12.8 13.3 13.1 13.4 13.9 14.4 14.2 14.6 15.1 15.7 15.2 15.6 16.1 16.8 16.2 16.6 17.2 17.9 17.2 17.6 18.3 19.0
HI PR 132 142 150 157 148 160 169 176 169 182 192 200 192 207 218 228 216 233 246 256 239 257 271 283
LO PR 59 63 69 73 63 67 73 78 65 69 76 81 69 73 80 85 72 76 83 89 74 79 86 92
MBh 49.6 51.0 55.2 59.3 48.4 49.8 53.9 57.9 47.3 48.7 52.7 56.5 46.1 47.5 51.4 55.1 43.8 45.1 48.8 52.4 40.6 41.8 45.2 48.5
S/T 0.80 0.71 0.54 0.35 0.83 0.74 0.56 0.36 0.85 0.76 0.57 0.37 0.87 0.78 0.59 0.38 0.91 0.81 0.61 0.40 0.92 0.82 0.62 0.40
Delta T222117122321 17 122321171223
21
17 12 23 21 17 12 21 19 16 11
1356 KW 3.24 3.31 3.41 3.52 3.49 3.56 3.68 3.80 3.71 3.79 3.91 4.04 3.90 3.99 4.12 4.25 4.06 4.15 4.29 4.44 4.21 4.30 4.44 4.59
AMPS 11.8 12.0 12.4 12.9 12.7 13.0 13.5 14.0 13.8 14.2 14.7 15.2 14.8 15.2 15.7 16.3 15.8 16.2 16.7 17.4 16.7 17.1 17.7 18.4
HI PR 128 138 146 152 144 155 164 171 164 176 186 194 186 201 212 221 210 226 238 249 232 249 263 275
LO PR 58 61 67 71 61 65 71 75 63 67 74 78 66 71 77 82 70 74 81 86 72 77 84 89
Shaded area is ACCA (TVA) conditions IDB: Entering Indoor Dry Bulb Temperature KW=Total system power AMPS=outdoor unit amps (comp.+fan)