Goodman Mfg RT6213004 Heat Pump User Manual


 
14
COOLING PERFORMANCE DATA GSH140421A*
EXPANDED PERFORMANCE DATA
COOLING OPERATION
MODEL: GSH140421A* / CA*F4860D6A*+TXV / MBR2000**-1 Design Subcooling, 9 ±3 °F @ the liquid service valve, ARI 95 test conditions
Outdoor Ambient Temperature
65 75 85 95 105 115
Entering Indoor Wet Bulb Temperature
IDB*Airflow 596367715963 67 7159636771596367715963677159636771
MBh 38.8 40.2 44.1 - 37.9 39.3 43.0 - 37.0 38.3 42.0 - 36.1 37.4 41.0 - 34.3 35.5 38.9 - 31.8 32.9 36.1 -
S/T 0.78 0.66 0.45 - 0.81 0.68 0.47 - 0.83 0.70 0.48 - 0.86 0.72 0.50 - 0.89 0.75 0.52 - 0.90 0.75 0.52 -
Delta T 18 15 12 - 18 16 12 - 18 16 12 - 18 16 12 - 18 15 12 - 17 14 11 -
1575 KW 2.58 2.63 2.71 - 2.76 2.82 2.90 - 2.92 2.98 3.07 - 3.06 3.13 3.22 - 3.18 3.25 3.35 - 3.29 3.35 3.46 -
AMPS 3.1 3.4 3.7 - 3.9 4.1 4.4 - 4.7 5.0 5.3 - 5.4 5.7 6.1 - 6.1 6.4 6.8 - 6.9 7.2 7.6 -
HI PR 136 146 155 - 153 164 173 - 174 187 197 - 198 213 225 - 222 239 253 - 246 265 279 -
LO PR 63 67 73 - 67 71 77 - 69 74 80 - 73 77 84 - 76 81 89 - 79 84 92 -
MBh 37.7 39.0 42.8 - 36.8 38.1 41.8 - 35.9 37.2 40.8 - 35.0 36.3 39.8 - 33.3 34.5 37.8 - 30.8 32.0 35.0 -
S/T 0.75 0.63 0.43 - 0.78 0.65 0.45 - 0.80 0.66 0.46 - 0.82 0.69 0.48 - 0.85 0.71 0.49 - 0.86 0.72 0.50 -
Delta T 19 16 12 - 19 16 12 - 19 16 12 - 19 16 12 - 19 16 12 - 17 15 11 -
70 1400 KW 2.57 2.62 2.69 - 2.74 2.80 2.88 - 2.90 2.96 3.05 - 3.04 3.10 3.20 - 3.16 3.22 3.32 - 3.26 3.33 3.43 -
AMPS 3.1 3.3 3.6 - 3.8 4.0 4.3 - 4.6 4.9 5.2 - 5.3 5.6 6.0 - 6.0 6.3 6.7 - 6.7 7.0 7.5 -
HI PR 135 145 153 - 151 163 172 - 172 185 195 - 196 211 223 - 220 237 250 - 243 262 277 -
LO PR 62 66 73 - 66 70 77 - 69 73 80 - 72 77 84 - 75 80 88 - 78 83 91 -
MBh 34.8 36.0 39.5 - 34.0 35.2 38.6 - 33.2 34.4 37.7 - 32.3 33.5 36.7 - 30.7 31.9 34.9 - 28.5 29.5 32.3 -
S/T 0.72 0.60 0.42 - 0.75 0.62 0.43 - 0.77 0.64 0.44 - 0.79 0.66 0.46 - 0.82 0.69 0.48 - 0.83 0.69 0.48 -
Delta T 19 16 12 - 19 17 13 - 19 17 13 - 19 17 13 - 19 16 12 - 18 15 12 -
1225 KW 2.51 2.56 2.63 - 2.68 2.74 2.82 - 2.84 2.89 2.98 - 2.97 3.03 3.12 - 3.09 3.15 3.24 - 3.18 3.25 3.35 -
AMPS 2.8 3.0 3.3 - 3.5 3.7 4.1 - 4.3 4.6 4.9 - 5.0 5.3 5.6 - 5.7 6.0 6.4 - 6.4 6.7 7.1 -
HI PR 131 141 148 - 147 158 167 - 167 179 190 - 190 204 216 - 214 230 243 - 236 254 268 -
LO PR 61 64 70 - 64 68 74 - 67 71 77 - 70 74 81 - 73 78 85 - 76 81 88 -
MBh 39.5 40.6 44.0 47.2 38.5 39.7 43.0 46.1 37.6 38.7 41.9 45.0 36.7 37.8 40.9 43.9 34.9 35.9 38.9 41.7 32.3 33.3 36.0 38.6
S/T 0.89 0.80 0.60 0.39 0.92 0.83 0.63 0.40 0.95 0.85 0.64 0.41 0.98 0.88 0.66 0.43 1.00 0.91 0.69 0.44 1.00 0.92 0.69 0.45
Delta T211916112119 16 11211916112119 16 11 20 19 16 11 19 18 15 10
1575 KW 2.60 2.65 2.73 2.81 2.79 2.84 2.92 3.01 2.95 3.01 3.10 3.19 3.09 3.15 3.25 3.35 3.21 3.27 3.38 3.48 3.31 3.38 3.49 3.60
AMPS 3.2 3.4 3.7 4.1 4.0 4.2 4.5 4.9 4.8 5.1 5.4 5.8 5.5 5.8 6.2 6.6 6.3 6.5 7.0 7.4 7.0 7.3 7.7 8.2
HI PR 137 148 156 163 154 166 175 183 175 189 199 208 200
215
227 237 225 242 255 266 248 267 282 294
LO PR 64 68 74 79 67 72 78 83 70 74 81 87 73 78 85 91 77 82 89 95 80 85 93 99
MBh 38.3 39.4 42.7 45.8 37.4 38.5 41.7 44.8 36.5 37.6 40.7 43.7 35.6 36.7 39.7 42.6 33.9 34.9 37.7 40.5 31.4 32.3 35.0 37.5
S/T 0.85 0.76 0.58 0.37 0.88 0.79 0.60 0.38 0.90 0.81 0.61 0.39 0.93 0.83 0.63 0.41 0.97 0.87 0.66 0.42 0.98 0.87 0.66 0.43
Delta T212016112220 16 11222016112220 16 11 22 20 16 11 20 19 15 10
75 1400 KW 2.58 2.63 2.71 2.79 2.76 2.82 2.90 2.99 2.92 2.98 3.07 3.17 3.06 3.13 3.22 3.32 3.18 3.25 3.35 3.45 3.29 3.36 3.46 3.57
AMPS 3.1 3.4 3.7 4.0 3.9 4.1 4.4 4.8 4.7 5.0 5.3 5.7 5.4 5.7 6.1 6.5 6.1 6.4 6.8 7.3 6.9 7.2 7.6 8.1
HI PR 136 146 155 161 153 164 174 181 174 187 197 206 198 213 225 234 223 239 253 264 246 265 279 291
LO PR 63 67 73 78 67 71 77 82 69 74 80 86 73 77 84 90 76 81 89 94 79 84 92 98
MBh 35.4 36.4 39.4 42.3 34.5 35.6 38.5 41.3 33.7 34.7 37.6 40.3 32.9
33.9
36.7 39.3 31.3 32.2 34.8 37.4 28.9 29.8 32.3 34.6
S/T 0.82 0.73 0.56 0.36 0.85 0.76 0.58 0.37 0.87 0.78 0.59 0.38 0.90 0.81 0.61 0.39 0.93 0.84 0.63 0.41 0.94 0.84 0.64 0.41
Delta T222016112220 17 11222017112220 17 12 22 20 17 11 20 19 15 11
1225 KW 2.53 2.58 2.65 2.73 2.70 2.76 2.84 2.92 2.86 2.91 3.00 3.09 2.99 3.05 3.15 3.24 3.11 3.17 3.27 3.37 3.21 3.28 3.38 3.48
AMPS 2.9 3.1 3.4 3.7 3.6 3.8 4.1 4.5 4.4 4.7 5.0 5.4 5.1 5.4 5.8 6.2 5.8 6.1 6.5 7.0 6.5 6.8 7.2 7.7
HI PR 132 142 150 156 148 159 168 176 168 181 191 200 192 206 218 227 216 232 245 256 238 257 271 283
LO PR 61 65 71 76 65 69 75 80 67 71 78 83 71 75 82 87 74 79 86 91 76 81 89 95
Shaded area is ACCA (TVA) conditions IDB: Entering Indoor Dry Bulb Temperature KW=Total system power AMPS=outdoor unit amps (comp.+fan)