Goodman Mfg High-Efficiency Split System Air Conditioner 1 To 5 Tons Up to 16 SEER Air Conditioner User Manual


 
2 www.goodmanmfg.com SS-GSX16
SS-GSX16 www.goodmanmfg.com 3
Product SPecificationS
Product SPecificationS
SpecificationS
GSX16
0181F*
GSX16
0241F*
GSX16
0301F*
GSX16
0361F*
GSX16
0421F*
GSX16
0481F*
GSX16
0601F*
GSX16
0611F*
Capacities
Nominal Cooling (BTU/h) 18,000 23,600 29,000 34,800 42,000 45,500 54,000 57,000
SEER 16 16 16 16 16 16 16 16
Decibels 71.5 71.5 71.5 71.5 73 73 73 73
Compressor
RLA 9.0 13.5 12.8 14.1 17.9 17.9 21.4 25
LRA 46 58.3 64 77 112 112 135 134
Condenser Fan Motor
Horsepower 1/6 1/6 1/6 1/6 1/6 1/4 1/3 1/4
FLA 1.10 1.10 1.10 1.10 1.10 1.50 2.80 1.50
Refrigeration System
Refrigerant Line Size ¹
Liquid Line Size (“O.D.) ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜"
Sucon Line Size (“O.D.) ¾" ¾” ⅞" ⅞" ⅞" ⅞" ⅞" ⅞"
Refrigerant Connecon Size
Liquid Valve Size (“O.D.) ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜"
Sucon Valve Size (“O.D.) ¾" ¾" ⅞" ⅞" ⅞" ⅞" ⅞" ⅞"
Valve Type Sweat Sweat Sweat Sweat Sweat Sweat Sweat Sweat
Refrigerant Charge 80 89 100 109 120 152 290 134
Electrical Data
Voltage-Phase (60 Hz) 208/230-1 208/230-1 208/230-1 208/230-1 208/230-1 208/230-1 208/230-1 208/230-1
Minimum Circuit Ampacity ² 12.4 18.0 17.1 18.7 23.5 23.9 28.3 32.8
Max. Overcurrent Protecon ³ 20 30 25 30 40 40 45 50
Min / Max Volts 197/253 197/253 197/253 197/253 197/253 197/253 197/253 197/253
Electrical Conduit Size ½" or ¾" ½" or ¾" ½" or ¾" ½" or ¾" ½" or ¾" ½" or ¾" ½" or ¾" ½" or ¾"
Ship Weight (lbs) 165 163 170 178 228 241 301 314
¹ Tested and rated in accordance with ARI Standard 210/240
² Wire size should be determined in accordance with Naonal Electrical Codes; extensive wire runs will require larger wire sizes
³ Must use me-delay fuses or HACR-type circuit breakers of the same size as noted.
Notes
Always check the S&R plate for electrical data on the unit being installed.
Installer will need to supply ⅞” to 1⅛” adapters for sucon line connecons.
Unit is charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per Installaon Instrucons Final Charge Procedure.
Installaon of these units requires the specied TXV Kit to be installed on the indoor coil. THE SPECIFIED TXV IS DETERMINED BY THE OUTDOOR UNIT NOT
THE INDOOR COIL.