WIRING DIAGRAMS
43
WARNING
HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS
UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
GPC14[24-48]H41AB
2
3
NOTE #2
WH
NOTE #4
EM
TR
24V
208-240
CONTROL
208-240/1/60
SUPPLY VOLTAGE
C
COMP
C
S.A.
S
T1
R
L1
C
NOTE #4
H
F
RCCF
CM
T2
C
L2
BOX
H
RCCF
C
YL
BR
PU
C
BK
PU
COMP
CM
BR
BR
PLF
PU
BK
YL
S
BK
RD
BK
CR
LVJB
RD
BL
BR
WH
GR
YL
R
C
W2
W1
G
Y
A
O
S
M
R
E
H
T2
T1
RD
BL
NOTE #3
PU
BL
GND
C
PU
BK
/
/
BL
BR
RD
RD
BK
BK
RD
YL
C
G N
BL
BL
RD
RD
GR
GR
GR
EM
GR
SEE NOTE 2
++
1
L
3 1
2
R W2 W1 Y G C
4
5
6
C
SEE NOTE #2
IF USED
N
G
SEE UNIT RATING PLATE FOR TYPE AND SIZE
OF OVER CURRENT PROTECTION
COMPONENT LEGEND
C
CM
COMP
EM
GND
LVJB
PLF
RCCF
SA
TR
CONTACTOR
CONDENSER MOTOR
COMPRESSOR
EVAPORATOR MOTOR
EQUIPMENT GROUND
LOW VOLTAGE JUNCTION BOX
FEMALE PLUG / CONNECTOR
RUN CAPACITOR FOR^J
COMPRESSOR AND FAN
START ASSIST
TRANSFORMER
WIRE CODE
BK BLACK
BL BLUE
BR BROWN
GR GREEN
OR ORANGE
PU PURPLE
RD RED
WH WHITE
YL YELLOW
FACTORY WIRING
LINE VOLTAGE
LOW VOLTAGE
OPTIONAL HIGH
VOLTAGE
FIELD WIRING
HIGH VOLTAGE
LOW VOLTAGE
NOTES:
1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS
ORIGINAL (AT LEAST 105°C) USE COPPER CONDUCTOR ONLY.
2. TO CHANGE EVAPORATOR MOTOR SPEED MOVE WHITE AND YELLOW
LEADS FROM EM "2" AND "3" TO "4" AND "5". IF BOTH LEADS ARE
ENERGIZED, THE HIGHER SPEED SETTING IS USED.
3. FOR 208 VOLT TRANSFORMER OPERATION MOVE PURPLE WIRES
FROM TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER.
4. START ASSIST FACTORY EQUIPPED WHEN REQUIRED
5. USE COPPER CONDUCTORS ONLY.
++ USE N.E.C. CLASS 2 WIRE
EM
C
SEE NOTE 5
YL
RD
SA
(IF USED) SEE NOTE 4
YL
WH
BK
PU
WH
YL
BK
5MM COILS