BLOWER PERFORMANCE SPECIFICATIONS
26
1. Units are shipped without filter(s). CFM in chart is without filter(s).
2. All furnaces shipped with heating speed set at "B" and cooling speed set at "D". Installer should adjust blower speed
as needed. The first task is to determine the proper aiflow for the cooling system.
3. For most cooling applications, about 400 CFM per ton is desirable.
4. The chart is for information only. For satisfactory operation, external static pressure not to exceed value shown on
rating plate.
5. Do not operate above 0.5" w.c. ESP in heating mode. Operating between 0.5" w.c. and 0.8" w.c. is tabulated for cooling
purposes only.
6. * Motor CFM minimum.
GMVC95/AMVC95 Continuous Fan Speed Chart
GCVC9/ACVC9 Continuous Fan Speed Chart
GCVC95/ACVC95 Continuous Fan Speed Chart
Model
Furnace Maximum
CFM
Continuous Fan
Speed
1,2
GMVC950453BX*
AMVC950453BX*
1400 420
GMVC950704CX*
AMVC950704CX*
1760 530
GMVC950905CX*
AMVC950905CX*
2200 660
GMVC950905DX*
AMVC950905DX*
2200 660
GMVC951155DX*
AMVC951155DX*
2200 660
1
Continuous fan speed is 30% of furnace maximum CFM
2
Three continuous fan speeds are possible with the CTK01AA
thermostat: 30%, 50%, and 70% of furnace maximum CFM
Model
Furnace Maximum
CFM
Continuous Fan
Speed
1,2
GCVC90704CX*
ACVC90704CX*
1760 530
GCVC90905DX*
ACVC90905DX*
2200 660
GCVC91155DX* 2350 705
2
Three continuous fan speeds are possible with the CTK01AA
thermostat: 30%, 50%, and 70% of furnace maximum CFM.
1
Continuous fan speed is 30% of furnace maximum CFM
Model
Furnace Maximum
CFM
Continuous Fan
Speed
1,2
GCVC950714CX*
ACVC950714CX*
1760 530
GCVC950915DX*
ACVC950915DX*
2200 660
1
Continuous fan speed is 30% of furnace maximum CFM
2
Three continuous fan speeds are possible with the CTK01AA
thermostat: 30%, 50%, and 70% of furnace maximum CFM.