Giant LP250 Plumbing Product User Manual


 
6
Specifications
Model LP250, LP250W-MT
Volume ........................................................................................................ Up to 26.0 GPM
Discharge Pressure .................................................................................... Up to 2200 PSI
Inlet Pressure.............................................................................................. Up to 90 PSI
Speed .......................................................................................................... Up to 1000 RPM
Plunger Diameter........................................................................................ 32 mm
Stroke.......................................................................................................... 42 mm
Crankcase Oil Capacity .............................................................................. 100 fl.oz.
Temperature of Pumped Fluids................................................................... Up to 140
o
F
Inlet Port ..................................................................................................... 1-1/24" BSP
Discharge Port............................................................................................ 3 x 1" BSP
Crankshaft Mounting .................................................................................. Either Side
Shaft Rotation ................................................................................Top of Pulley Towards Fluid End
Weight ......................................................................................................... 110 lbs.
Crankshaft Diameter .................................................................................. 35 mm
* Intermittent duty for pump speeds in excess of 805 RPM
PULLEY INFORMATION
Pulley selection and pump speed are based on
a 1725 RPM motor and "B" section belts. When
selecting desired GPM, allow for a ±5% toler-
ance on pumps output due to variations in
pulleys, belts and motors among manufactur-
ers.
1.Select GPM required, then select appropriate
motor and pump pulley from the same line.
2.The desired pressure is achieved by selecting
the correct nozzle size that corresponds with
the pump GPM.
HORSEPOWER INFORMATION
We recommend that a 1.1 service factor be
specified when selecting an electric motor as
the power source. To compute specific pump
horsepower requirements, use the following
formula:
HP = (GPM X PSI) / 1440
LP250 HORSEPOWER REQUIREMENTS
RPM GPM 1000 PSI 1500 PSI 2000 PSI 2200 PSI
500 13.0 9.0 13.5 18.0 19.8
640 16.6 11.5 17.3 23.1 25.4
750 19.5 13.5 20.3 27.1 29.8
805 20.9 14.5 21.8 29.0 31.9
865
22.5 15.6 23.4 31.2 34.3
920
23.9 16.6 24.9 33.2 36.5
1000 26.0 18.0 27.1 36.1 39.7