Volume.............................................................Up to 75.5 GPM ...... (285 LPM)
Discharge Pressure ..........................................Up to 3000 PSI ........ (200 bar)
Speed ...............................................................Up to 580 RPM ....... 580 RPM
Inlet Pressure ...................................................Up to 29 PSI............ (2.0 bar)
Plunger Diameter .............................................2.17” ........................ 55mm
Plunger Stroke .................................................2.83” ........................ 72mm
Crankshaft Diameter........................................2.76” ........................ 70mm
Key Width........................................................0.55” ........................ 14mm
Crankshaft Mounting......................................................................... Either side
Shaft Rotation .................................................................................... Top of pulley towards manifold
Temperature of Pumped Fluids ....................... Up to 140
o
F ............ (60
o
C)
Inlet Ports .......................................................................................... (2) 3" BSPP
Discharge Ports.................................................................................. (2) 1-1/4" BSPP
Weight .............................................................. 705 lbs. .................... (320kg)
Crankcase Oil Capacity ...................................3.3 Gal. .................... (12.5 liters)
Fluid End Material............................................Nickle plated Spheroidical Cast Iron
Specifications
Model GP8055
Consult the factory for special requirements that must be met if the pump is to
operate beyond one or more of the limits specified above.
HORSEPOWER RATINGS:
The rating shown are the power
requirements for the pump. Gas
engine power outputs must be
approximately twice the pump
power requirements shown above.
We recommend a 1.1 service factor
be specified when selecting an
electric motor as the power source.
To compute specific pump horse
power requirements, use the
following formula:
GPM X PSI
SPECIAL NOTE:
The theoretical gallons per revolution (gal/rev) is 0.130.
To find specific outputs at various RPM, use the formula:
GPM = 0.130 x RPM
= HP
1400
3
GP8055 HORSEPOWER REQUIREMENTS
RPM GPM 500 PSI 1000 PSI 2000 PSI 3000 PSI
300 39 13.9 27.9 55.7 83.6
400 52 18.6 37.1 74.3 111.4
500 65 23.2 46.4 92.9 139.3
580 75.5 27.0 53.9 107.9 161.8