Gianni Industries ST-630E Door User Manual


 
Copyright All Rights Reserved. Page 4 of 5
P-MU-ST-630 Ver. A Publish: 2009.01.08
Controller and Reader can open different doors.
34*99#
Reset the function of
Anti Pass Back.
35*x# (for connecting
controller)
x=1=
access record to duty
x=0= access record Not to Duty
(x= default is 0)
x=0 Green LED is controlled by Controller x=1 Green LED is
controlled by external system
38*x#
(The second Relay contact to the Door Status and
negatron (-)
Green LED flash can
synchronize with Security System.
51*99#
Reset to Default, and clean the controller memory to the factory
default
Add New Cardsread card once and 1 Beep heard for adding the
new card. Read card twice and 2 Beep heard to delete the cards.
55*99#
(After add Cardsthe default access mode is “Card Only”)
70*X# For LCD series X=0 Screen Backlight ON x=1 Screen Backlight Off automatically
Emergent Code SettingEnter twice 6-Digital Code
71*XXXXXX XXXXXX #
Enter the Code can link to the other relay to activate the external
system. 22*xxx # for setting the active time. (second)
72*xxx#
xxx=000~255 Seconds
Door Left Open Alarm Time Delay - The door does not close after the
limited time, and the controller will output the alarm.
73*x #
x=1 Enter the emergent code or press 99* with Security Cards, the
relay of the controller/ ON; X=0 OFF
74*x# X=1 Door Left Open Alarm and Force Open Mode are ON; X=0 OFF
76*x#
X=1 Emergent Alarm /ONx=0 OFF
When setting or Release the External Relay, Please enter the
codes99*and then read the security card.
99*
(Operating in the Normal Mode.)
Ⅴ、 Wiring diagram: