Indicators Status and Default Value
Beep & LED indication:
Mode
Signal
Status
Yellow(flashing
slowly)
Power-on, stand-by
Green On Valid entry, door relay active
Normal
Red
Warning, invalid card or code, tamper, alarm relay
active
Yellow(flashing
Quickly)
Enter Programming Mode.
LED
Programming
Red flashing
Quickly)
Card read, or clear the memory
1 Beep
Invalid cardkeypressentry program mode
Normal
2 Beep Invalid cards, Mistake Codes
1 Beep Valid Entry, exit the Program Mode.
Beep
Programming
2 Beep Input mistake or other failure operation
Factory Default Setting:
Access Mode Card only (0000)
Card Memory All Bits
Transaction Memory MAX 1000 cards
0 pcs
Master codes (Master Password) *123456#
(All) Functions of Alarm Clear the function (00)
Door Relay Time 5 Seconds
Key Timeout 5 Seconds
Awaiting code timeout 5 Seconds
Programming mode timeout 25 Seconds