Genie 3060 Garage Door Opener User Manual


 
10
For Help, call 1-800-35-GENIE or visit www.geniecompany.com
A Monthly:
Door springs and door hardware:
Oil door roller, bearings, and hinges using silicone
lubricant or light oil.
Balance Door.
Close door.
Release Carriage Assembly from Rail Assembly by pulling
the Emergency Release Knob towards the door.
Raise door manually 3’- 4’ and verify that door stays at
that position. See Check Step 2 on page 4.
Reattach Carriage Assembly to Rail Assembly:
a.
Pull the Emergency Release Knob toward
Power Head.
b. Close door.
Contact Reverse Test.
Perform Adjustment 2 on page 8.
NOTE
When the door is 3’ - 4’ above the ground, the door
should stay open. Slight movement is acceptable. If
the door moves too much, contact a Genie Factory
Authorized Dealer for service or call Customer Service at
1-800-35-GENIE.
WARNING:
Do not operate door automatically or manually if springs
are broken. Contact a Genie Factory Authorized Dealer for
service or call Customer Service at 1-800-35-GENIE.
If the door fails to reverse on contact with the board,
adjust the Close Force Control as specified in Set Limit
Switches and Force Controls on page 7 & 8. If the Opener
still fails, contact a Genie Factory Authorized Dealer for
service or call Customer Service at 1-800-35-GENIE.
NOTE
Use ONLY Genie Lubricant (GLU-3). Other lubricants
may damage the Opener.
FCC AND IC CERTIFIED
All devices comply with Part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1)
this device may not cause harmful interference, and (2)
this device must accept any interference received, includ-
ing interference that may cause undesired operation.
GLU-3
Lubricant
MAINTENANCE
B Yearly:
Wipe off old excess lubricant from Drive Screw.
Lubricate Drive Screw with Genie Lubricant (GLU-3)
C As needed
Replace lightbulbs. (See page 9)
Safe-T-Beam® System Self-Diagnostic Troubleshooting
Source (Red LED) Sensor (Green LED) Possible Problem Solution
ON ON Normal operation None required
OFF OFF
• Power Head not powered • Check breakers, fuses, plugs
• Wiring from Power Head bad • Check wiring for obvious shorts
OFF ON
• Wiring to Source missing or bad • Check wiring
• Power has been interrupted • Remove power and reapply
2 BLINKS, Pause • Beam not aligned • Check Source, Sensor alignment
(Repeat) ON • Beam obstructed • Check for obstruction
• Sensor defective • Contact Customer Service
2 BLINKS, Pause • Wire to Sensor missing or bad • Check wiring
(Repeat)
OFF
• Sensor defective • Contact Customer Service
3 BLINKS, Pause • Sensor receiving interference • Determine source of interference
(Repeat)
ON
• Check for interference from sun-
light or a source unit on an
adjacent door
• Contact Customer Service
4 BLINKS, Pause • Source not sending pulses • Contact Customer Service
(Repeat)
ON
• Source defective • Contact Customer Service
TROUBLESHOOTING
WARNING: