Genie 3024H Garage Door Opener User Manual


 
NOTICE
IF DOOR BECOMES OBSTRUCTED
PULL DOWN ON HANDLE
TO RELEASE CARRIAGE:
1. Pull handle DOWN then let go.
2. Manually move door until carriage releases from bullet.
3. Raise or lower door manually.
DOOR
PULL
TO RECONNECT CARRIAGE:
1. Verify RED block is in the UP position.
2. Manually move door until carriage engages bullet.
3. Raise or lower door using remote or wall console.
Release
Handle
DISENGAGEENGAGE
(for installation)
TO REENGAGE PULL
DOWN AND TOWARD
POWERHEAD THEN
LET GO
(for installation)
TO DISENGAGE
PULL DOWN AND
TOWARDS DOOR
THEN LET GO
DOOR
TO RELEASE or RECONNECT CARRIAGE,
PULL DOWN AND LET GO
DOOR
FIG. 6-4 Carriage Release (cut away view)
CARRIAGE ENGAGE/DISENGAGE
Use Release Handle to manually connect or release
chain or belt bullet to Carriage.
FIG. 6-3 Carriage Release
CHANGE LIGHT BULBS
WARNING
Observe all safety warning and precautions!
Improper light bulb removal or replacement
could result in Death or Serious Injury.
Disconnect power from opener before
beginning this task.
When replacing light cover, make sure wires are
not pinched or near moving parts.
1. Disconnect power to door opener.
• Open powerhead light cover.
• Remove light bulb(s).
• Replace with maximum 100 Watt light bulb(s).
Do NOT use light bulbs with greater than
100 Watt rating.
• Close powerhead light cover.
2. Reconnect power to door opener.
• Test light operation.
©2010 The Genie Company 12/2010
19
RESET - OPEN/CLOSE TRAVEL LIMIT
Performing all ten (10) Limits/Force setting steps
(pages 6-7) erases previous Limits/Force settings.
NOTE: The opener will not close the door
automatically unless the Safe-T-Beam® System is
installed and Limits are programmed.
MOTION DETECTOR* - OVERVIEW
(Not available on all models)
Powerheads equipped with a motion detector
sensor provide additional security when
exiting or entering the garage area.
*This sensor works by detecting body heat. Range of detection may be
reduced when the temperature in the garage is close to body temperature.
NOTE: Detector positioning on the powerhead provides
for monitoring below the powerhead.
OPERATION
Detector sensor is always ON. There are NO user
controls or adjustments.
Lights automatically turn ON when a change is
detected and will turn OFF after 4 minutes of no
change.
Motion detector sensor will not turn OFF lighting
turned ON at the wall console.
• Lighting turned ON at the wall console will remain
ON until wall console turns lighting OFF or opener
is used.
Motion Detector