GE Monogram 5800 Series Air Conditioner User Manual


 
8
Zoneline
®
Features
AZ AZ AZ
2900 3900 5800
Enhanced Dehumidification — Dry Air 25 Optional N/A N/A
Cooling EER Range (230 Volts/265 Volts) 10.2 - 12.7 10.0 - 12.7 10.2 - 13.0
Heating COP Range (230 Volts/265 Volts) N/A 3.2 - 3.6 3.2 - 3.6
Heat Source — Electric Resistance Heat Standard
Heat Source — Heat Pump With Selectable
Full Time or On Demand Simultaneous/
Supplemental Resistance Heat Standard Standard
Staged Heating 3 Stage 3 Stage
Universal Heater — UPC* Standard Standard Standard
Unit Controls Touch Pad Touch Pad Touch Pad
Electronic Temperature Selection
(Slews Up & Down) with Digital Display Standard Standard Standard
Unit Diagnostics Standard
Highly Featured Microprocessor Controls Standard Standard Standard-Plus
Electric Resistance Heat Lock-Out (above 46°F) Standard Standard
Automatic Emergency Heat Standard Standard
Heat Pump Defrost System Reverse Cycle Reverse Cycle
High Temperature Operation Protection Standard Standard
Quick Heat Recovery Standard Standard
Temperature Boost Selectable Selectable
Service Indicator Temp Display Blinks
Fan Motors — Permanently Lubricated 2 2 2
2-Speed Outdoor Fan Standard Standard Standard
Indoor Fan Speed Selections — HIGH/LOW HIGH/LOW/AUTO HIGH/LOW/AUTO HIGH/LOW/AUTO
Fan Only Setting — HIGH/LOW Standard Standard Standard
Fan Cycle Switch “Smart Fan” “Smart Fan” “Smart Fan”
Constant-Run Fan Selectable Selectable Selectable
Rotary Compressor Standard Standard Standard
Automatic Compressor Restart Delay Standard Standard Standard
Freeze Sentinel
Standard Standard Standard
Heat Sentinel Standard Standard Standard
Indoor Coil Frost Control Standard Standard Standard
Transfer Fan Connections Standard Standard Standard
7-Step Electronic Temperature Limiting Standard Standard Standard
Remote Control Capability with Wall Mounted Thermostat Standard Standard Standard
Central Desk Control Capability Standard Standard Standard
Energy Management System Interface with Load Shedding Option Standard Standard Standard
Reversible Indoor Air Louvers 40º/50º Standard Standard Standard
Up-Front Filters Standard Standard Standard
Easy-Clean Air Discharge Area Standard Standard
Concealed Manual Vent Control Standard Standard Standard
Ducted Installation Capability RAK6052 RAK6052
Corrosion Protection (Standard on Dry Air 25) Optional Optional Standard
Internal Condensate Removal (ICR) (Factory Installed Option.
Cannot be used in Corrosion Areas.) N/A Optional Optional
*UPC — Universal Power Cord Connection (See pages 42 and 54).
265-volt units must be connected in a manner to meet National Electrical Code and all local codes.