GE QS2800V Heat Pump User Manual


 
2.2 Performance Specifications
2.2.1 Pump Performance
Table 2.1
Pump Performance
Summary
*
Standard model pumps shown. Higher pressures are available upon request.
2.2.2 All QSV Pumps - IMPORTANT!
There is no limit on pumping capacity when operating QSV pumps in parallel.
The discharge pressure of your QSV pump may be increased by 100 psig (6.9
barg) by connecting another pump in series ahead of the QSV pump. Care
must be taken, however, so that the inlet pressure to any QSV pump does not
exceed the 100 psig (6.9 barg) maximum inlet pressure rating.
There must be adequate flow through the pump at all times to prevent exces-
sive heat build-up.
3
Series
QS1800V
QS2800V
Max.
Efficiency
56%
64%
Max.
Efficiency
57%
51%
Capacity
gpm (m
3
/h)
5 - 21
(0.25 - 1.1)
10 - 40
(2.3 - 9.1)
Maximum
Boost*
psi (bar)
420 (29.0)
350 (24.1)
Capacity
gpm (m
3
/h)
7 - 15
(1.6 - 3.4)
9 - 34
(2.0 - 7.7)
Maximum
Boost*
psi (bar)
280 (19.3)
245 (16.9)
60 Hz Operation
(3450 rpm)
50 Hz Operation
(2875 rpm)