GE PNSF35B Water System User Manual


 
18
About the water softener system.
Service: Manually Advance Regeneration Check
This check verifies proper operation of the valve motor, brine tank fill, brine draw, regeneration flow rates
and other controller functions. First, make the initial checks and the
Manually Initiated Electronic Diagnostics.
NOTE:
The control display must show a steady time (not flashing).
Press the
TOUCH or HOLD
button and hold in for three seconds.
RECHARGE NOW
begins to flash as the water
softening system enters the fill cycle of regeneration. Remove the brinewell cover and, using a flashlight,
observe fill water entering the brine tank.
If water does not enter the tank, look for an obstructed nozzle, venturi, fill flow plug or brine tubing.
See
Care and cleaning of the water softener system
section.
After observing fill, press the
TOUCH or HOLD
button to move the water softening system into brining.
A slow flow of water to the drain will begin. Verify brine draw from the brine tank by shining a flashlight
into the brinewell and observing a noticeable drop in the liquid level over an extended period of time.
NOTE:
Be sure a salt bridge is not preventing water from contacting salt. See
Care and cleaning of the water
softening system
section.
If the water softening system does not draw brine, check:
nozzle and/or venturi dirty or defective.
nozzle and venturi not seated properly on gasket.
restricted drain (check drain fitting and hose).
defective nozzle and venturi seal.
other inner valve defect (rotor seal, rotor & disc, wave washer, etc.).
NOTE:
If water system pressure is low, an elevated drain hose may cause back pressure, stopping brine draw.
Again, press the
TOUCH or HOLD
button to move the water softening system into backwash. Look for a fast
flow of water from the drain hose.
A slow flow indicates a plugged top distributor, backwash flow plug, or drain hose.
Press the
TOUCH or HOLD
button to move the water softening system into fast rinse. Again look for a fast
drain flow. Allow the water softening system to rinse for a few minutes to flush out any brine that may
remain in the resin tank from the brining cycle test.
To return the water softening system to service, press the
TOUCH or HOLD
button.
5
4
3
2
1