GE Lamps Indoor Furnishings User Manual


 
GE LIGHTING - ENTERTAINMENT LIGHTING CATALOGUE
76
C-1.0µF
250V
R-33
2.5W
Ballast G53307. T
20A
HBC/MCB
Fuse
PFC
175µF 250V
7xGC2346
L
N
220/240V
50Hz
Supply
B
G53444 or
Bag Turgi
SE 15/7U
Igniter
1000W CID Lamp
Ref 99-1225
or 99-0222
Lampholder for 99-1222 - Bender & Wirth 938/223 and for 99-0222- Bender & Wirth 933/1419
R/C components necessary ONLY when used on a 220V rate supply
Maximum cable capacitance between igniter and lamp - 50pF (300mm length)
Replace G53445 (or Bag Turgi SE600/D) igniter sparkgap element when replacing a failed lamp
Lp
N
9kV
Lamp
1000 Watt CIDLamp Circuit Diagram
Ballast G53307. T
20A
HBC/MCB
Fuse
PFC
175µF 250V
7xGC2346
L
N
220/240V
50Hz
Supply
Sw
Biassed Off
R-5
6W
C-6µF
300V
Irem
AD1540
Igniter
1000W CSI Lamp
Ref 99-0421
or 99-1422
1000W CID Lamp
Ref 99-0422
or 99-1425
Sw - Normally open contacts - Manual switch or 2 second ON timer
Maximum cable capacitance between igniter and lamp - 30pF (200mm length)
1
2
2
3
G
Lampholder
Bender & Wirth
type 938/223
HT
HT
40kV
Lamp
1000 Watt CSI/CIDHot-Restart Lamp Circuit Diagram
Discharge lamps continued
Ballast G53307. T
20A
HBC/MCB
Fuse
PFC
150µF 250V
7xGC2346
L
N
220/240V
50Hz
Supply
Sw
Biassed Off
R-15
2.5W
C-2µF
250V
Irem
AD1550
Igniter
1200W CID Lamp
Ref 99-1435
Sw - Normally open contacts - Manual switch or 2 second ON timer
Maximum cable capacitance between igniter and lamp - 30pF (200mm length)
1
2
2
3
G
Lampholder
Bender & Wirth
type 938/223
HT
HT
50kV
1200 Watt CIDHot-Restart Lamp Circuit Diagram
Ballast
2xG53307. T in parallel
40A
HBC/MCB
Fuse
PFC
275µF 250V
11xGC2346
L
N
220/240V
50Hz
Supply
Sw
R-50
2.5W
C-2µF
250V
2500W CID Lamp
Ref 99-0431
Sw - Normally open contacts - Manual switch or 2 second ON timer
Maximum cable capacitance between igniter and lamp - 30pF (200mm length)
Irem
AD3050
Igniter
1
2
2
3
G
HT
HT
50kV
Biassed Off
Lampholder
Bender & Wirth
type 938/223
2500 Watt CIDHot-Restart Lamp Circuit Diagram
GE S&S 2000 9/03/00 9/3/00 1:31 pm Page 78