GE Lamps Indoor Furnishings User Manual


 
GE LIGHTING - ENTERTAINMENT LIGHTING CATALOGUE
74
Discharge lamps continued
Ballast G53398. T
10A
HBC/MCB
Fuse
PFC
35µF 250V
GC2382
L
N
220/250V
50Hz
Supply
Sw
Biassed Off
R-100
2.5W
C-1µF
250V
HT HT
12kV
Output
Irem
AD312/R
Igniter
200W CID Lamp
Ref 99-0211
Sw - Normally open contacts - Manual switch or 2 second ON timer
Maximum cable capacitance between igniter and lamp - 30pF (200mm length)
123E
SG
200 Watt CIDHot-Restart Lamp Circuit Diagram
Ballast G53371 .T
13A
HBC/MCB
Fuse
PFC
40µF 250V
2xGC2331
L
N
220/250V
50Hz
Supply
C-0.47µF
250V
B
G53444 or
Bag Turgi
SE 15/7U
Igniter
400W CSI
Ref 99-0201
Maximum cable capacitance between igniter and lamp - 50pF (300mm length)
Lp
N
R-100
2.5W
9kV
400 Watt CSILamp Circuit Diagram
GE S&S 2000 9/03/00 9/3/00 1:31 pm Page 76