GE GXWH20F Water System User Manual


 
3
Installation Overview
NOTE: Be sure to allow a minimum space of 1
1
2
under the filter for removing the sump, to change
the cartridge.
GXWH04F
GXWH20F
Recommended
shut-off valve
Recommended
shut-off valve
Select Location
Select a location for the filter that is:
protected from freezing.
not exposed to direct sunlight.
It is recommended that a shut-off valve be placed on both sides
of the filter.
It is recommended that a mounting bracket be used.
Install Fittings and Mounting Bracket
Instructions are for installing fittings supplied with the filter
(on some models) or the WHKIT onto 3/4copper plumbing.
If the unit is to be installed on any other type of tubing (plastic,
PVC, galvanized), different hardware must be purchased. See
instructions with additional hardware purchased, or consult
a qualified plumber.
Apply about 12of Teflon tape, in a clockwise
direction, to the pipe threads of each fitting.
DO NOT
use joint compound on any parts.
Use the bracket as a template to find the
two screw locations. Wood screws are provided. If mounted
onto other surface, use appropriate hardware.
Drill a 3/16hole on each marked screw location (optional),
then drive the two wood screws until about 1/4of thread
is left. Ensure at least one screw is anchored into wall stud.
Assemble a fitting through the mounting bracket hole to
the inlet and outlet of the head. Start each fitting by hand
to make sure they don’t cross thread. Use a 1
1
8wrench to
tighten fittings firmly.
DO NOT OVERTIGHTEN.
4
3
2
1
Cut Water Line
WARNING:
A copper or galvanized cold water pipe may be used to ground
electrical outlets in the home. Failure to maintain this ground
path may result in an electric shock hazard. If the cold water pipe
is used to ground electric outlets, please refer to
Installing the
Ground Wire
section before cutting the pipe.
Turn off the water supply and open a nearby faucet to drain
the water out of the pipes.
Using a tape measure or ruler, measure the distance “D”
as shown.
NOTE:
I
t is recommended that the shut-off valve be placed
before and after the filter as shown in the
Installation Overview
illustration.
Select a secure location to install the filter and mounting
bracket. The location should align the filter housing with the
inlet and outlet pipes and should not cause the pipes to bend.
Mark the distance “D” on the pipe. D is about 5
1
4for
GXWH04F model and 5
3
4for GXWH20F model.
Using a pipe cutter, cut pipe. Sand (file) the cut ends of the
pipe to assure that they are square and smooth.
NOTE:
Have a bucket and towel available to collect excess water.
3
2
1
Measure to shoulder
of fittings. Copper
pipe butts against
this shoulder.
D
D
GXWH04F
GXWH20F
Recommended
shut-off valve
Recommended
shut-off valve
GXWH04F
GXWH20F
Teflon tape
STEP-BY-STEP INSTALLATION INSTRUCTIONS