ABOUT THE FILTER CARTRIDGE
Filter Cartridge Replacement
You should change your filter when the water flow is noticeably reduced or at least every 3 months.
Replacement Filter Cartridges
Several variables determine how long the cartridge will
last in your Household Water Filtration Housing. These
include:
levels of sediment or other undesirable substances in
your water.
the amount of water you use.
the filter location (filtering all or part of your
household water).
GE MODEL FUNCTION LIFE CONSTRUCTION
FXUSC (Rev. 2) Sediment* 3 month/16,000 gallons* Polypropylene Fiber
FXWPC Sediment* 3 month/16,000 gallons* Pleated
FXWSC Sediment* 3 month/16,000 gallons* String Wound
10 Micron
FXWTC (Rev. 2) Sediment* 3 month/15,000 gallons* Carbon Paper
5 Micron
Chlorine
*Above data are based on manufacturer’s internal testing.
Turn off water to filter. For model GXWH04F, water
must be shut off from an upstream valve. For model
GXWH20F, rotate control handle to the BYPASS or
OFF position. (See
Control Handle
.)
Press the red pressure release button to release
pressure.
Unscrew the filter canister and discard used filter.
Wash the filter canister with mild soap and water.
Do
not
use harsh cleaners or hot water.
Inspect the filter canister O-ring. Make sure it is
lightly lubricated with clean food grade silicone
grease (silicone grease is available through GE Parts
and Service: 1.800.626.2002, part number
WS60S10005). Be sure the O-ring is seated in the
groove. It is recommended that you replace the
O-ring if it is damaged.
Place a new filter cartridge into the canister, making
sure it is centered and completely seated on the
bottom seal.
Reinstall the filter canister to the unit. Tighten filter
canister to seal. Use canister wrench if necessary.
Slowly rotate control handle to the FILTER position
(model GXWH20F) or slowly turn on the upstream
shut-off valve (model GXWH04F).
Press the red pressure release button to remove
trapped air.
Open any downstream faucet and allow filter system
to flush for 5 minutes.
9
8
7
6
5
4
3
2
1
Turn canister wrench
clockwise to remove
Filter canister
Control
handle
Filter
cartridge
O-ring seal
Timer
Head
Timer
Filter
cartridge
O-ring seal
Filter canister
Head
GXWH04F
GXWH20F
Red pressure
release button
Red pressure
release button
Filter canister
Control Handle (GXWH20F Model Only)
OFF
Shuts off water.
FILTER
For filtered water. Directs water
flow through filter.
BYPASS
Permits flow of water to the house without flowing
through the filter. Use this position for filter
changes or if filtered water is not desired.
2
Rated Service Flow: 8 gpm
Minimum–Maximum Supply Water Pressure: 20–125 psi
Minimum–Maximum Supply Water Temperature: 40–100°F
INFLUENT CHALLENGE REDUCTION
SUBSTANCE CONCENTRATION REQUIREMENT
Particulate, Class V particles 30 to < 50 At least 1,000 particles/mL > + 85%
Rated Service Flow: 4 gpm
Performance Data Sheet
GXWH20F system using FXUSC (Rev. 2) filter has been tested according
to NSF/ANSI 42 for reduction of the substances listed below. The
concentration of the indicated substances in water entering the system
was reduced to a concentration less than or equal to the permissible limit
for water leaving the system, as specified in NSF/ANSI 42. While testing
was performed under standard laboratory conditions, actual performance
may vary.