GE GNSF35Z Water System User Manual


 
Before you call for service…
22
Problem Possible Causes What To Do
Salty tasting or Unit not sanitized Complete the Sanitization Procedures on page 12.
brown/yellow colored
At completion of recharge cycle (approx. 2 hrs), run water
water after installation
from faucets to purge the salty water.
Low water pressure Check pressure.
Drain height 8or less, pressure should be minimum of 20 psi.
Drain height above 8, pressure should be minimum of 50 psi.
Restricted drain hose Clean and reconnect hose.
Check for kinks in drain line.
Brown/yellow Unit was idle for a period of time Complete the Sanitization Procedures on page 12.
colored water
Resin beads showing Cracked distributor Call for service.
up in drinking water
and sink
Sounds you might hear Running water from the unit This is normal.
into a drain during recharge
Water has air bubbles Air in system after installation Will go away after it runs for a while.
and is cloudy
Error Code on control Wiring may have worked loose See page 16 for details.
in the control
Unplug transformer.
Remove control cover, release clips on side.
Check for loose/incorrect wiring connections to electronic
board or switch. Reconnect as required.
Reassemble control cover.
Plug in Transformer.
Wait six minutes for Error Code to reappear.
If Error Code reappears, call for service.
Troubleshooting Tips