There are 3 ways to remove collected water:
Use the bucket. When the bucket is removed,
the unit will shut off. Empty and replace the
bucket.
Use a hose. Water can be automatically
emptied into a floor drain by attaching a
water hose (not included) to the bucket hose
nozzle. Using a drill, make a hole at the end
of the nozzle located on the lower left side of
the bucket. Attach a water hose to the bucket
nozzle. Fasten by hand only.
Use a floor drain. The unit can also be placed
over a floor drain. Using a drill, make a hole
at the end of the nozzle located on the lower
left side of the bucket.
NOTE: The nozzle cannot be fixed after puncture. Use
an ordinary garden hose cap (not included) to reclose
if necessary.
NOTE: Avoid using mechanical tools to tighten the
water hose to the bucket nozzle. This may damage the
threads on the nozzle.
Always make sure the water bucket is locked into place on the dehumidifier.
Installing the Water Bucket
Lift the bucket and hook the slots on each side
onto the posts on the back of the dehumidifier.
The bucket should lock securely in place.
Make sure the bucket is locked securely in place
by pressing down on the upper back edge of the
bucket. It will be firmly seated when properly
installed.
Water Level
The dehumidifier will turn off automatically
when the bucket is full, or when the bucket is
removed or not replaced in the proper position.
The bucket must be replaced in the proper position for
the dehumidifier to work. The light will be on and the
dehumidifier will not run if the bucket is not in the
proper position.
Consumer Support
Troubleshooting Tips
Operating Instructions Safety Instructions
Troubleshooting Tips
Care and Cleaning Safety InstructionsOperating Instructions
Using the dehumidifier.
Post
Post
Removing Collected Water
Drill
Nozzle
Hose
Attach hose:
6
Drill hole:
Drill