GE AJCH 08 ACB, AJCH 10 ACB, AJCH 10 DCB, AJCH 12 DCB, AJOQ 06 LCB, AJOQ 08 ACB, AJOQ 10 ACB, AJOQ 10 DCB, AJOQ 12 DCB, AJGS 06 LGB, AJGS 08 ACB, AJGS 10 ACB, AJGS 09 DCB, AJGS 10 DCB, AJGS 12 DCB, AJEH 12 DCB, AJES 06 LSB, AJES 08 ASB, AJES 09 DGB, AJES 10 Air Conditioner User Manual


 
6
Consumer Support Troubleshooting Tips Installation Instructions Care and Cleaning Operating Instructions Safety Instructions
About the controls on the air conditioner—models with touch pads.
Auxiliary Controls – Temperature Limiting
To reach the auxiliary controls remove the front
grille. Access them through the small rectangular
opening above the control panel.
Temperature limiting can reduce energy
costs by limiting the lowest temperature that
can be set for cooling. Temperature limiting is
controlled by switches 1–3 of auxiliary controls.
Temperature limiting during COOL mode
(all temperatures shown in °F)
UP DOWN Minimum Maximum
NONE 1, 2, 3 60° 85°
1 2, 3 64° 85°
1, 2 3 66° 85°
2 1, 3 68° 85°
2,3 1 70° 85°
1, 2, 3 NONE 72° 85°
1, 3 2 74° 85°
3 1, 2 76° 85°
1 32 4
UP
DOWN
TL1 (C) (Temp. Limit 1 – Cool)
TL2 (C) (Temp. Limit 2 – Cool)
TL3 (C) (Temp. Limit 3 – Cool)
No function (reserved
for future use)