GE AES15 Air Conditioner User Manual


 
Imtallation
Imtructiom
~PORTANT:
~ave
these instructions with the appliance.
OWNER:
Wep
these instructions for future use.
Electrical
Safetv—
The
Dower
cord on these models
IMPORTANT...
Please Read Carefully.
has
~
230/208-volt perpendicular,
tandem or large tandem type plug
that mates
resDectivelv
with a
230/208-volt
~erpend~cular,
How to connect electricity
tandem or large tandem type wall
For personal safety, this
outlet. These types of outlets are
available at most hardware stores.
appliance must be properly
grounded.
Electrical requirement
230/208-volt
models
require their
own single branch circuit supplying
230/208-volt
a.c.,
protected with a
time delay fuse or circuit breaker.
This is recommended for best
performance and to prevent
overloading house wiring circuits,
which could cause a possible fire
hazard from overheating wires.
Q@
230/208-VOLT
MATCHING
PERPENDICULAR TYPE WALL OUTLET
LINE CORO PLUG
REQUIRES 20 AMP TIME DELAY FUSE
OR CIRCUIT BREAKER
PROTEUION
@@
230/208-VOLT
MATCHING
TANDEM TYPE
WALL OUTLET
LINE CORD PLUG
REQUIRES 15 AMP TIME DELAY FUSE
OR CIRCUIT BREAKER PROTECTION
@o
.0
@
mm
(’
230/208-VOLT
MATCHING
LARGE
TANOEM
TYPE
WALL OUTLET
LINE CORO PLUG
REQUIRES 30 AMP TIME DELAY FUSE
OR CIRCUIT BREAKER
PROTE~lON
It is important to have the wall
outlet and circuit checked by a
qualified electrician if there is
any doubt as to whether a proper
ground
exis@.
Use of
etinsion
cords
not recommended
Because of potential safety
hazards under certain conditions,
we
stron~y
recommend against the
use of an extension cord.
However,
if you
stifl
elect to use an extension
cord, it is absolutely necessary that
it be a
UL
listed 3-wire grounding
type appliance extension cord and
that the current carrying rating of
the cord in amperes be equal to or
greater than the branch circuit size
shown on the rating nameplate of
the appliance.
7