GE 49218 Air Conditioner User Manual


 
10
11
RAK201 (AZC and AZ Series*)
Access Plate Cover
The RAK201 access plate cover is made of heavy-gauge steel
with multiple knockouts for special applications. Will adapt to
service conduit .875" or 1.125"; circuit breaker up to 30 amp or
30 amp receptacle. The RAK201 fits old sub-bases RAK120,
RAK121 and RAK122 for easy replacement of A-B series with
AZC and AZ series.
RAK7022 (AZ Series*—2200, 2500, 2800, 3200,
3500 and 3800 only)
Duct Transition for Replacement
of AZC with Rounded Front AZ Chassis
The RAK7022 duct transition is designed to allow duct installation where
the original chassis was a slope front discharge (AZC/AZR/AZ21/AZ31)
chassis. Using the RAK7022 will allow the existing duct adapter and
extension to be used without requiring the relocation of the hole through
the wall to the adjacent room.
RAK204 (AZ Series*—2200, 2500, 3200 and 3500 only)
Standard Sub-Base
The RAK204 sub-base is made of heavy-gauge steel to provide support of the
wall case. It has full base enclosure with break-away side channels, simple
connection to wall case, and 4-point leveling legs. The sub-base will adapt to
service conduit, circuit breakers and receptacles up to 30 amps. It may also be
used as a non-electrical sub-base to provide support for the unit.
Circuit
Kit No. Sub-Base Ampacity Chaseway Power Cord
RAK204U** Standard N/A Not Included Not Included
RAK204D20 Sub-Base 230/208V 15 & 20 Included Not Included
RAK204D30 Sub-Base 230/208V 30 Included Not Included
RAK204E15 Sub-Base 265/277V 15 Included Not Included
RAK204E20 Sub-Base 265/277V 20 Included Not Included
RAK204E30 Sub-Base 265/277V 30 Included Not Included
Power cord and junction box
not included with sub-base.
Chaseway
* A-B Series: Zonelines built before 1987 – Zoneline I, II, III, and IV; AZC Series: Zonelines built from 1987 to 1992 – includes AZR Series – Zoneline 1000, 2000, 2500, 2700, 3000,
4000, 5000; AZ Series: Zonelines built after 1992 – Zoneline 2100, 3100, 2600, 5100 / Zoneline 2200, 3200, 5200 / Zoneline 2500, 3500, 5500 / Zoneline 2800, 3800, 5800.
Zoneline
®
units
Zoneline units
RAK205CW
(AZ Series*—2200, 2500, 2800, 3200, 3500, 3800, 5200, 5500
and 5800 only)
Chaseway
Chaseway for wiring containment between junction box on
chassis and RAK204U sub-base.
RAK702 (AZ Series*—2100 and 3100 only)
Duct Transition for Replacement of
AZC with Sloped Front AZ Chassis
The RAK702 duct transition is designed to allow duct installation
where the original chassis was a slope front discharge (AZC or
AZR) chassis. Using the RAK702 will allow the existing duct
adapter and extension to be used without requiring the
relocation of the hole through the wall to the adjacent room.
RAK7012 (AZ Series*—2200, 2500, 3200, 3500,
2800 and 3800 only)
Duct Adapter for Replacement of
A-B with Rounded Front AZ Chassis
The RAK7012 duct adapter is designed to line up with the duct
extension where the original chassis was a flat-top discharge
A-B Series. Using the RAK7012 will allow the existing duct
extension to be used without requiring the relocation of the hole
through the wall to the adjacent room. Discharge grille, end
plate, and extension mounting hardware must be removed from
old duct adapter and installed on the RAK7012.
8-3/8"
6-1/2"
Chaseway
RAK204 (AZ Series*—2800, 3800, 5200, 5500 and 5800 only)
Standard Sub-Base
The RAK204 sub-base is made of heavy-gauge steel to provide support
of the wall case. It has full base enclosure with break-away side channels, simple
connection to wall case, and 4-point leveling legs. The sub-base will adapt to
service conduit, circuit breakers and receptacles up to 30 amps. It may also be
used as a non-electrical sub-base to provide support for the unit.
Circuit
Kit No. Sub-Base Ampacity Chaseway Power Cord
RAK204D15P Sub-Base 230/208V 15 Included Included
RAK204D20P Sub-Base 230/208V 20 Included Included
RAK204D30P Sub-Base 230/208V 30 Included Included
RAK5157/5207/5307
(AZ Series*—2800, 3800, 5500 & 5800 only)
265/277-Volt Universal Power Supply Kit
• 9-pin connector with three 7" 12-gauge conductor wires.
Circuit
Kit No. Volts Heater Wattage Ampacity
RAK5157 265/277 2.55 kw 15
RAK5207 265/277 3.45 kw 20
RAK5307 265/277 5.00 kw 30
* A-B Series: Zonelines built before 1987 – Zoneline I, II, III, and IV; AZC Series: Zonelines built from 1987 to 1992 – includes AZR Series – Zoneline 1000, 2000, 2500, 2700, 3000,
4000, 5000; AZ Series: Zonelines built after 1992 – Zoneline 2100, 3100, 2600, 5100 / Zoneline 2200, 3200, 5200 / Zoneline 2500, 3500, 5500 / Zoneline 2800/3800/5800.
**RAK204U May be used with AZC and AZ 2100, 3100, 2600 and 5100.
†The power connection kit determines the heater wattage and current requirements when it is plugged into the Zoneline unit. NOTE: All power cord kits and permanent
connection kits may be used on all units (of matching voltage). NOTE: 7,000 BTU models do not have 5,000 watt heaters.