GE 268 Water System User Manual


 
28 Level II Programming
Rev A
Level II Programming
Level II program parameters are those parameters used to fine-tune a
conditioners operation. These are accessible by pressing and holding the
UP and DOWN buttons until the display goes blank. Then release the
buttons. Calendar Override is the first Level II parameter displayed. Level II
program parameters include:
268 Conditioner Operation Type 263 Filter Operation Type
CALENDAR OVERRIDE CALENDAR OVERRIDE
SALT AMOUNT REGEN SU
CAPACITY K GRAIN REGEN MO
HARDNESS GPG REGEN TU
SELECT LANGUAGE REGEN WE
CLOCK MODE REGEN TH
UNITS OF MEASURE REGEN FR
INJECTOR SELECTION* REGEN SA
BACKWASH 1 CAPACITY GAL
SLOW RINSE SELECT LANGUAGE
FAST RINSE 1 CLOCK MODE
BACKWASH 2 UNITS OF MEASURE
FAST RINSE 2 BACKWASH
OPERATION TYPE 268* FAST RINSE
SERVICE INTERVAL OPERATION TYPE 263*
CHLORINE GENERATOR SERVICE INTERVAL
CHLORINE GENERATOR
*View only.
Level II parameters will, in almost all cases, be preset to meet your
configuration needs. The predefined system number will preprogram all of
the Level II parameters to the selected default values.
Setting the Calendar Override
Calendar Override allows the programmer to set the maximum days
between regenerations. A setting of 0 (zero) means the calendar
override is disabled. To change the calendar override, press the SET
button while the words “CALENDAR OVERRIDE" appear on the banner
display. The blinking digit can be changed to the desired numbers of
days. To lock in the parameter, press the SET button.
WARNING: Setting days between regeneration to zero will cause the
system to not regenerate. This setting is used for selecting regeneration
on specific days or to use with a remote regeneration input. See below.