GE 000 gpd to 288 Water System User Manual


 
4
Rejection = [(C
avg
) - (C
P
)] x 100
(C
avg
)
= [(237.5 mg/L) + (8.3 mg/L)] x 100
(237.5)
= 96.5%
Passage = (C
P
) x 100
(C
f
)
= (8.3 mg/L) x 100
(237.5)
= 3.5%
Recovery = (Q
P
) x 100
(Q
f
)
= (18 gpm) x 100
(24gpm)
= 75%