PRE-INSTALLATION CHECKS
Check that the Flue or Chimney is structurally sound. In particular, it should not be possible
for products of combustion to come into contact with combustible materials in the structure of
the building.
Check the flue draught. This should be done with all windows and doors closed and any
extraction fans in adjoining rooms running at maximum speed. (See next section for additional
ventilation requirements)
Note: A guide containing general information on Chimneys and Flues is obtainable from: -
The British Flue & Chimney Manufacturers’ Association,
FETA
2 Waltham Court
Milley Lane
Hare Hatch
Reading
Bucks RG10 8TH
Tel :-
01189 403416 e-mail :- info@feta.co.uk
2. ADDITIONAL VENTILATION
Additional ventilation will be required to comply with the requirements of the Building
Regulations. This should be provided using a permanently open vent, of the size listed, which
is positioned so that it is not liable to be blocked, both inside and outside the building.
Area: Stockton 8 Integral Boiler - 1650mm
2
(16.5cm
2
)
Extractor fans or cooker hoods should not be placed in the same room or space as the
Stockton stove.
If any of these checks reveal problems do not proceed with the fitting of the stove until
they have been rectified.