1. GENERAL POINTS
1.1 Before use of this appliance please read these
instructions fully.
1.2 All local regulations, including those referring to national
and European Standards need to be complied with when
installing the appliance.
1.3 Only use for domestic heating in accordance with these
operating instructions.
1.4 You must burn only approved fuels. Do not use with liquid
fuels or as an incinerator.
1.5 Appliance surfaces become very hot when in use. Use a
suitable fireguard if young children, elderly or infirm persons
are present.
Stovax offer firescreens, sparkguards and hearthgate systems
for protection*. Your Stovax dealer can advise you about
these products.
1.6 Do not place photographs, TV’s, paintings, porcelain or
other combustible items on the wall or near the appliance.
Exposure to hot temperatures will cause damage.
1.7 Extractor fans or cooker hoods must not be placed in the
same room or space as this can cause appliance to emit
fumes into the room.
1.8 Do not obstruct inside or outside ventilation required for
the safe use of this appliance.
1.9 Do not make unauthorised changes to the appliance.
1.10 The chimney must be swept at least once a year.
See Section 12
1.11 Do not connect, or share, the same flue or chimney
system with another appliance.
SERIAL NUMBER
This number will be required when ordering spare parts or
making any warranty claims. It is found on the Data plate.
PRODUCT:
MODEL No.
SERIAL No.
PR8001
Base Plate
1.12 To access the data plate:
If a Contemporary Steel Frame is fitted, lift the frame off,
see Installation Instructions Section 3 Fitting Of Frames.
If fitted remove multi-fuel kit or log tray before lifting out
the base plate, see Installation Instructions Section 2 Fitting
Of Fuel Kits.
•Liftoutthebaseplate,diagram1
AIR CONTROLS
Convection principle
Convector boxes convert more of the potential heat in fuel
than an open hearth.
1) Air is drawn in below the firebox
2) It is heated in the convection chambers on both sides
and below the firebox.
3) Warm air passes out into the room giving additional
radiated heat.
For Damper Controls, See Diagram 3
To operate: Move the Damper Control using the tool provided
DO NOT OPERATE WITH BARE HANDS
PR8068
Open
Close
*In the U.K: These products must conform to BS 6539,
Fireguards for use with solid fuel appliances.
If appliance is operating unattended they must conform to
BS 3248