INSTALLATION INSTRUCTIONS
TECHNICAL SPECIFICATION
COVERING THE FOLLOWING MODELS:
CLARENDON – 8611LUC – P8611LUC / 8612LUC – P8612LUC
ASHDON – 8613LUC – P8613LUC / 8614LUC – P 8614LUC
Model Gas Gas Working NOX Aeration Injector Gas Rate Input kW (Gross) Country
CAT. Type Pressure Class m
3
/h High Low
8611LUC I
2H
Natural 20 mbar 3 Ø 14.5 375 0.623 6.6 3.6 GB, IE
8612LUC (G20) Gross Gross
P8611LUC I
3P
Propane 37 mbar 3 Ø 11.5 x 2 165 0.232 6.4 3.6 GB, IE
P8612LUC (G31) Gross Gross
8613LUC I
2H
Natural 20mbar 3 Ø 14.5 375 0.623 6.6 3.6 GB, IE
8614LUC (G20) Gross Gross
P8613LUC I
3P
Propane 37mbar 3 Ø 11.5 x 2 165 0.232 6.4 3.6 GB, IE
P8614LUC (G31) Gross Gross
Packing Checklist
Qty Description
1 Stove
1 Flue Blanking plate
1 Coal Retainer
1 Log set (5 logs)*
2 Ash Panels* (2 sections)*
1 Fixing Kit Containing
1 Instruction Manual
1 Wood Screw
1 Rawplug
1 Box spanner
*Packed in appliance
A B C D E
ins mm ins mm ins mm ins mm ins mm
25
3
/
4
654 25
3
/
4
652 16
3
/
4
427 18
1
/
4
463 5 126
1
AR1618
Efficiency Class II
Flue Outlet Size 127mm (5”) Ø
Gas Inlet Connection Size 8mm Ø
Minimum Flue Specification T260 / N2 / 0 / D / 1
Maximum Flue Temperature 180°C