Stovax 7017 Stove User Manual


 
10
SITE REQUIREMENTS
Before installation of this product please read these
instructions fully.
It is very important to also understand the requirements of the UK
Building Regulations (England and Wales – Document J / Scotland
- Part F, Eire - Document J), along with any local regulations
and working practices that may apply. Should any conflict
occur between these instructions and these regulations then the
regulations shall apply.
Your local Building Control Office would be happy to advise
should questions arise, regarding the requirements of the
regulations.
The stove must be fitted by a HETAS (GB only)/INFO (Eire)
registered installer, or approved by your local building control
officer. Your Stovax dealer should be able to arrange this service
for you.
Your building insurance company may also require you to inform
them that you have installed a new heating appliance, so check
with your insurers that your cover is still valid after installing the
stove.
Description Model A B C D E F G
Sheraton
7016
7017
7027
630 597 150 550 100 375 115
All dimensions in mm. (25.4 mm = 1”)
A
B
C
D
F
E
G
When completing the installation and building works you should
comply with your responsibilities under the Health and Safety at
Work Acts, and any new regulations, which may be introduced
during the lifetime of these instructions.
A faulty installation could cause danger to the inhabitants and
structure of the building.
SHERATON STOVE DIMENSIONS