MODEL
PTS/U 40 40,000 40,000 25,000
PTS/U 50 50,000 50,000 30,000
PTS/U 75 75,000 75,000 50,000
PTS/U 100 100,000 100,000 65,000
MODEL SELECTIONS
GENERAL FEATURES
• 8 different Btu/hr sizes and more than 100
different configurations to custom design your
i
nfrared heating system
• Single Stage or Two Stage Input Controls
• CSA design certified
•
Vented or indirect vented operation
• Sidewall or through-the-roof venting
• Natural and propane gas models
PUSH THROUGH SYSTEM (
Positive Pressure)
• Products of combustion are pushed through the
combustion chamber
• Tube Integrity Safety System (TISS)
• No draft hoods, totally enclosed
combustion chamber
• Blower motor totally enclosed in the burner box.
Ideal for applications where minimal noise (less
than 60dB) is desired
• Heavy duty permanently lubricated, ball bearing
blower motor for maintenance-free operation
BURNER SYSTEM
• Heavy-duty cast iron burner
• 10-year limited warranty on burner
• Inside or outside air for combustion
• Up to 40 ft. outside combustion air duct capability
• Standard 4” combustion air collar
• Reliable direct spark ignition system and 100%
gas shut-off safety control
• Pre-purge and post-purge function
• State-of-the-art step opening redundant
combination gas valve for quiet ignition and
added safety
• Diaphragm air switch for proof of venting before
gas flow and ignition
• Diagnostic monitoring light system
• Burner inspection sight glass
• Line voltage or 24V thermostat connection
RADIANT EMITTER TUBE SYSTEM
• 4” O.D. heavy-duty calorized aluminized steel or
alumi-therm steel combustion chamber (10 feet)
a
nd heavy duty hot-rolled steel radiant emitter
tubes
• Optional calorized aluminized steel (ALC)
radiant emitter tubes
• 3-year limited warranty on the emitter tubes
• Suitable for horizontal or angle mounting up to 45°
• Optional 90° elbows
• Up to 40 feet sidewall vent capacity
REFLECTOR SYSTEM
• Highly efficient aluminum reflectors with
reflectivity rating of 97.5%
• Optional end, corner, side and U-bend reflectors
• Optional decorative grille
• Individual reflectors can be rotated up to 45° to
direct heat where needed
• Easy-to-use mounting brackets and wire hangers
TOTAL EMITTER TUBE LENGTH*
10 FT** 20 FT 30 FT 40 FT
P
TS/PTU SERIES FEATURES
GAS
TYPE
NATURAL 3.5” W.C. 5” W.C* 14” W.C.
PROPANE 10” W.C. 11” W.C.* 14” W.C.
BURNER
PRESSURE
VOLTAGE
AMPS
IGNITION
TYPE
MIN MAX
120 VAC
60 HZ
1.8
DIRECT
SPARK
*Indicate model number based on Btu/hr input (e.g., 100,000 Btu/hr), total emitter length, (e.g., 40 feet) and gas type
(e.g., natural gas single stage input). The unit selection for a straight tube would be PTS100-40-N5 and for a U-tube
would be PTU100-40-N5. **Available only on PTS models.
ALC Option: All calorized aluminized steel (ALC) radiant emitter tubes
for ALC option the model number would be PTS100-40-ALC-N5. Note: for Carwashes, Dairy Barns, Greenhouses,
Swimming Pools,Waste WaterTreatment Plants, and other high humidity / corrosive environments, the ALC option with
all calorized aluminized tubes is recommended.
SUPPLY PRESSURE
SINGLE
STAGE
BTU/HR
INPUT
FLUE
CONNECTION
OUTSIDE COMBUSTION
AIR CONNECTION
4” Round 4” Round
Btu/hr
High Input
Btu/hr
Low Input
TWO STAGE
X
X
X
X
X
X
X
X
MODEL
PTS/U 125 125,000 125,000 80,000
PTS/U 150 150,000 150,000 100,000
PTS/U 175 175,000 175,000 110,000
PTS/U 200 200,000 200,000 125,000
TOTAL EMITTER TUBE LENGTH*
30 FT 40 FT 50 FT 60 FT 70 FT
SINGLE
STAGE
BTU/HR
INPUT
Btu/hr
High Input
Btu/hr
Low Input
TWO STAGE
X
X
X
X
X
X
X
X
X
X
X
X
CONTROL SUFFIX
N5 / L5
N7 / L7
TYPE OF GAS
Natural / Propane
Natural / Propane
CONTROL OPTION DESCRIPTION
Single Stage Gas Valve - Single Stage Input
Two Stage Gas Valve - Two Stage Input - High/Low Fire
®
Energy efficient PTS150-40 installed in a manufactur-
ing application.