Fujitsu R410A Air Conditioner User Manual


 
9
TEMPERATURE SET BACK TIMER
Press the SET BACK button to change to the SET BACK con-
rmation display.
The SET BACK operating time and the set temperature will
be displayed.
2
Press the SET button for 2
seconds or more.
1
3
l Day setting l Operating time setting
Follow the same procedures to set the operating time as those for the weekly timer. The DELETE button is also used
as described in the procedures for the weekly timer.
4
NOTES
The SET BACK timer only changes the set temperature, it cannot be used to start or stop air conditioner operation.
The SET BACK timer can be set to operate up to two times per day but only one temperature setting can be used.
The SET BACK timer can be used together with the ON, OFF, and weekly timer functions.
The SET BACK operating time is displayed only in the SET BACK con rmation display. (Refer to step 1 for the SET BACK
con rmation display.)
SET BACK
SU
MO
TU
WE
TH FR
SA
369
12 15 18 21
SU
MO
TU
WE
TH FR
SA
369
12 15 18 21
ex. When setting all days together
l Temperature setting
Press the set temperature buttons to set
the temperature. (The temperature setting
range is the same as the range for the
operation mode.)
ex. Operating time 15:0022:00
5
Repeat steps 3 and 4.
Press the SET button for 2 sec-
onds or more to complete the
temperature SET BACK timer
settings.
ON OFF
24°C
24°C
28°C
SET BACK temperature
Normal temperature
l To start
SET BACK
Press the SET BACK button. The SET BACK con rmation display appears
for 5 seconds, and then the timer starts automatically.
ex. Display during SET BACK timer operation
(The operating time will not be displayed.)
l To cancel
Press the SET BACK button, and then
press the DELETE button while the
SET BACK con rmation display is dis-
played. Even if the SET BACK button
is pressed again, the SET BACK timer
will be cancelled.
SU
MO
TU
WE
TH FR
SA
369
12 15 18 21
If there is no existing
SET BACK tempera-
ture setting, - - will
be displayed for the
temperature.
SU
MO
TU
WE
TH FR
SA
1
3
2
4
1
2
Temperature SET BACK timer setting
Temperature SET BACK timer operation
9374379354.indd Sec1:99374379354.indd Sec1:9 12/17/08 9:59:23 AM12/17/08 9:59:23 AM